SELECTED-ION ACCUMULATION FROM AN EXTERNAL ELECTROSPRAY-IONIZATION SOURCE WITH A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER

被引:62
作者
BRUCE, JE [1 ]
ANDERSON, GA [1 ]
HOFSTADLER, SA [1 ]
VANORDEN, SL [1 ]
SHERMAN, MS [1 ]
ROCKWOOD, AL [1 ]
SMITH, RD [1 ]
机构
[1] PACIFIC NW LAB, DEPT CHEM SCI, CHEM METHODS & SEPARAT GRP, RICHLAND, WA 99352 USA
关键词
D O I
10.1002/rcm.1290071012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling of an electrospray ionization (ESI) source to a Fourier-transform ion cyclotron resonance (FTICR) mass spectrometer provides a facility for the high resolution, accurate mass analysis of large biopolymers. Typically the m/z range of the electrosprayed ions injected and trapped in the FTICR cell is between m/z 500 and 2500 (but can vary considerably with solution conditions). Recent reports on quadrupole excitation have demonstrated the ability to cool the magnetron motion of ions trapped in the FTICR mass spectrometer cell by converting this motion to cyclotron motion which, under appropriate pressure conditions, damps readily to the center of the cell. The use of a broadband waveform (swept frequency or stored waveform inverse Fourier-transform) for the quadrupole cooling pulse was shown to provide cooling of a wide range of m/z ions, while implementation of a single frequency demonstrated a much narrower m/z response. This report demonstrates the successful combination of single-frequency quadrupole cooling with external injection of electrosprayed ions into an FTICR mass spectrometer for m/z selected-ion accumulation. This capability is particularly significant with electrospray ionization since it allows ions of only one charge state to be accumulated in the cell, and greatly increases the potential dynamic range of ESI-FTICR.
引用
收藏
页码:914 / 919
页数:6
相关论文
共 20 条
[1]  
ALEKSANDROV ML, 1984, DOKL AKAD NAUK SSSR, V277, P379
[2]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[3]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[4]  
BRUCE JE, UNPUB BIOMED ENV MAS
[5]   SIMPLE PHYSICAL MODELS FOR COULOMB-INDUCED FREQUENCY-SHIFTS AND COULOMB-INDUCED INHOMOGENEOUS BROADENING FOR LIKE AND UNLIKE IONS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, SP ;
COMISAROW, MB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) :450-455
[6]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[7]   OPTIMAL CYCLOTRON RADIUS FOR HIGH-RESOLUTION FT-ICR SPECTROMETRY [J].
GORSHKOV, MV ;
NIKOLAEV, EN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 125 (01) :1-8
[8]   ENHANCED MASS RESOLVING POWER, SENSITIVITY, AND SELECTIVITY IN LASER-DESORPTION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY BY ION AXIALIZATION AND COOLING [J].
GUAN, SH ;
WAHL, MC ;
WOOD, TD ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1753-1757
[9]   REMEASUREMENT OF ELECTROSPRAYED PROTEINS IN THE TRAPPED ION CELL OF A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
GUAN, ZQ ;
HOFSTADLER, SA ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1588-1593
[10]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449