CARDIAC-OUTPUT FROM CARBON-DIOXIDE PRODUCTION AND ARTERIAL AND VENOUS OXIMETRY

被引:27
作者
MAHUTTE, CK
JAFFE, MB
SASSOON, CSH
WONG, DH
机构
[1] LONG BEACH VET AFFAIRS MED CTR, DEPT MED, LONG BEACH, CA USA
[2] LONG BEACH VET AFFAIRS MED CTR, DEPT ANESTHESIOL, LONG BEACH, CA USA
[3] UNIV CALIF IRVINE, IRVINE, CA 92717 USA
关键词
CARDIAC OUTPUT; METABOLISM MONITORING; PHYSIOLOGICAL; OXIMETRY; THERMODILUTION; OXYGEN CONSUMPTION; CARBON DIOXIDE; CATHETERIZATION; PULMONARY ARTERY; OXYGEN;
D O I
10.1097/00003246-199110000-00009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To determine cardiac output from measurements of CO2 production (V(CO2)), and arterial (Sa(O2)) and mixed venous (SVBARO2) oxygen saturations, using a modified Fick equation, in which cardiac output = V(CO2)/[k (Sa(O2) - SVBARO2], where k represents a constant. Design: A metabolic measurement cart was used to measure V(CO2) and oxygen consumption (V(O2)) at 3-min intervals. Sa(O2) and SVBARO2 were measured via a pulse oximeter and a fiberoptic right heart catheter, respectively. The initial value of k for each study was determined from initial simultaneous measurements of thermodilution cardiac output, V(CO2), Sa(O2), and SVBARO2 via the equation k = V(CO2)/[cardiac output (Sa(O2) - SVBARO2]. The value of k was assumed to remain constant for the entire study period. Thereafter, cardiac outputs calculated from k and the measurements of V(CO2), Sa(O2), and SVBARO2 were compared with the simultaneously obtained cardiac outputs determined by thermodilution. Similarly, cardiac outputs calculated from the traditional oxygen Fick equation, where cardiac output = V(O2)/[13.4 X hemoglobin (Sa(O2) - SVBARO2)], were compared with the simultaneously acquired cardiac outputs determined by thermodilution. Setting: Surgical ICU in a Veterans Affairs Medical Center. Patients: Seven postoperative patients, mechanically ventilated using the intermittent mandatory ventilation mode, were studied over a mean period of 4 hrs. Results: Cardiac output (obtained from V(CO2) and oximetry saturations) was closely related to thermodilution cardiac output: with linear regression showing r2 = .96 and standard error of the estimate = 0.59 L/min, n = 21; and, with bias and precision = 0.17 and 0.68 L/min, respectively. The traditional oxygen Fick cardiac output was also closely related to the thermodilution cardiac output (r2 = .81, standard error of the estimate = 1.46 L/min, n = 22; bias and precision = 0.31 and 1.46 L/min, respectively). Conclusion: The proposed method for calculating cardiac outputs solely from V(CO2) and oximetry saturations yields results that correspond closely to thermodilution determined cardiac outputs. The method is simple and avoids the difficulties in the Fick method associated with accurate V(O2) measurement. This approach may be suitable for continuous cardiac output monitoring in critically ill patients.
引用
收藏
页码:1270 / 1277
页数:8
相关论文
共 32 条