DETERMINATION OF PHENOXYACID HERBICIDES IN DRINKING-WATER AT THE PPT-LEVEL BY LIQUID-CHROMATOGRAPHY AND ONLINE SELECTIVE PRECONCENTRATION

被引:35
作者
COQUART, V
HENNION, MC
机构
[1] Ecole Supérieure de Physique et Chimie de Paris, Laboratoire de Chimie Analytique, 75231 Paris Cedex 05
关键词
PHENOXY ACIDS; ONLINE PRECONCENTRATION; HPLC; WATER;
D O I
10.1016/0048-9697(93)90143-T
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
On-line precolumn sample handling using an anion-exchanger is applied to preconcentrate phenoxyacid herbicides in aqueous samples prior to their LC separation. Since direct percolation of large sample volumes through the ion-exchanger has to be avoided owing to the high content of inorganic anions in natural waters, a two-step preconcentration is carried out: phenoxyacids are concentrated in their neutral (acidic) form by percolation of natural samples at pH 1 first through a precolumn packed with the copolymer-based PRP-1 sorbent. Then, the PRP-1 precolumn is coupled on-line with a second one packed with the anion-exchanger and 3 ml of deionised water with 35% of acetonitrile allows the phenoxyacids to be desorbed from the PRP-1 sorbent and reconcentrated on the anion-exchanger in their ionic form. The content of the anion-exchanger is analysed on-line by coupling with a C18 analytical column and elution is made with a water-acetonitrile gradient. Detection limits in drinking water from a 500-ml sample are between 15 and 35 ng/l (ppt) and identity of phenoxyacids is reinforced by the fact that analytes are preconcentrated by the anion-exchanger. This methodology can be full automated.
引用
收藏
页码:349 / 360
页数:12
相关论文
共 28 条
[1]   SIMPLE PRECOLUMN SAMPLE ENRICHMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR DETERMINATION OF PHENOXY ACID HERBICIDES IN WATER SAMPLES FROM EXPOSURE STUDIES [J].
AKERBLOM, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 319 (03) :427-431
[2]  
ALLENDER WJ, 1990, J CHROMATOGR SCI, V27, P193
[3]   A REVIEW OF LIQUID-CHROMATOGRAPHY IN ENVIRONMENTAL PESTICIDE ANALYSIS [J].
BARCELO, D .
CHROMATOGRAPHIA, 1988, 25 (10) :928-936
[4]   SEPARATION AND DETERMINATION OF ACIDIC HERBICIDES ON A PRP-1 POLYMERIC COLUMN [J].
BETTI, A ;
LODI, G ;
COPPI, S .
JOURNAL OF CHROMATOGRAPHY, 1990, 513 :219-225
[5]   GAS-CHROMATOGRAPHIC AND SPECTRAL PROPERTIES OF PENTAFLUOROBENZYL DERIVATIVES OF 2,4-DICHLOROPHENOXYACETIC ACID AND PHENOLIC PESTICIDES AND METABOLITES [J].
CLINE, RE ;
TODD, GD ;
ASHLEY, DL ;
GRAINGER, J ;
MCCRAW, JM ;
ALLEY, CC ;
HILL, RH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (04) :167-172
[6]   INTERFERENCE REMOVAL IN THE ORGANIC TRACE-LEVEL ANALYSIS OF AQUEOUS ENVIRONMENTAL-SAMPLES BY ONLINE LIQUID-CHROMATOGRAPHIC PRECONCENTRATION TECHNIQUES WITH 2 PRECOLUMNS [J].
COQUART, V ;
HENNION, MC .
JOURNAL OF CHROMATOGRAPHY, 1991, 553 (1-2) :329-343
[7]   DETERMINATION OF CHLOROTRIAZINES IN AQUEOUS ENVIRONMENTAL-SAMPLES AT THE NG/1 LEVEL USING PRECONCENTRATION WITH A CATION EXCHANGER AND ONLINE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COQUART, V ;
HENNION, MC .
JOURNAL OF CHROMATOGRAPHY, 1991, 585 (01) :67-73
[8]   SENSITIVE AND SELECTIVE FLUORESCENCE DETECTION OF PHENOXYACID HERBICIDES BY LIQUID-CHROMATOGRAPHY WITH ONLINE ION-PAIR EXTRACTION [J].
DERUITER, C ;
MINNAARD, WA ;
LINGEMAN, H ;
KIRK, EM ;
BRINKMAN, UAT ;
OTTEN, RR .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 43 (2-3) :79-90
[9]   EXTRACTION AND ISOLATION OF PHENOXY ACID HERBICIDES IN ENVIRONMENTAL WATERS USING 2 ADSORBENTS IN ONE MINICARTRIDGE [J].
DICORCIA, A ;
MARCHETTI, M ;
SAMPERI, R .
ANALYTICAL CHEMISTRY, 1989, 61 (13) :1363-1367
[10]   ONLINE CONTINUOUS-FLOW EXTRACTION SYSTEM IN LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET AND MASS-SPECTROMETRIC DETECTION FOR THE DETERMINATION OF SELECTED ORGANIC POLLUTANTS [J].
FARRAN, A ;
CORTINA, JL ;
DEPABLO, J ;
BARCELO, D .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :119-126