REPRODUCIBILITY OF NURSE-MEASURED, EXERCISE AND AMBULATORY BLOOD-PRESSURE AND ECHOCARDIOGRAPHIC LEFT-VENTRICULAR MASS IN BORDERLINE HYPERTENSION

被引:20
作者
REEVES, RA
LEENEN, FHH
JOYNER, CD
机构
[1] UNIV TORONTO, DEPT MED, DIV CLIN PHARMACOL, TORONTO M5S 1A1, ONTARIO, CANADA
[2] UNIV TORONTO, DEPT MED, DIV CARDIOL, TORONTO M5S 1A1, ONTARIO, CANADA
[3] TORONTO WESTERN HOSP, DIV CLIN PHARMACOL, TORONTO M5T 2S8, ONTARIO, CANADA
关键词
BLOOD PRESSURE DETERMINATION; HYPERTENSION; EXERCISE TEST; ECHOCARDIOGRAPHY; AMBULATORY BLOOD PRESSURE; RELIABILITY STUDY;
D O I
10.1097/00004872-199210000-00020
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To compare the short-term reproducibility of four diagnostic tests: resting blood pressure, exercise blood pressure, non-invasive daytime ambulatory blood pressure and echocardiographic left ventricular mass. Design: Blinded, prospective test-retest (reliability) study. Setting: Hypertension research units in two teaching hospitals. Participants: Six normal volunteers and 22 patients with untreated borderline to mild hypertension, mean age 44 years. Main outcome measures: The intraclass correlation coefficient (R(I)) and standard deviation of the difference (SDD) between visits. Main results: The mean blood pressures and left ventricular mass did not differ between visits. Concordance between visits reached R(I) = 0.86 systolic/0.66 diastolic for ambulatory blood pressure and R(I) = 0.85 systolic/0.64 diastolic for nurse-measured random-zero sphygmomanometer resting blood pressure. The respective variabilities were SDD = 9/8 and 8/8 mmHg. Submaximal exercise systolic blood pressure (SBP) and echo left ventricular mass showed excellent reliability. Echo left ventricular mass and resting SBP or ambulatory SBP were significantly more reproducible than resting diastolic blood pressure (DBP) or ambulatory DBP. Conclusions: Despite averaging many readings within each day, clinically important between-visit variations in ambulatory blood pressure remained. The between-visit variability of daytime ambulatory blood pressure was similar to that of resting blood pressure when carefully measured by a research nurse. The echo left ventricular mass appears to be more reproducible over the short term than the current diagnostic standard for hypertension, the resting DBP.
引用
收藏
页码:1249 / 1256
页数:8
相关论文
共 45 条
[1]  
[Anonymous], 1971, STAT PRINCIPLES EXPT
[2]  
ARMITAGE P, 1966, CLIN SCI, V30, P325
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CAEN JL, 1978, ARCH MAL COEUR VAISS, V71, P47
[5]   SERIAL ECHOCARDIOGRAPHIC EVALUATION OF LEFT-VENTRICULAR FUNCTION IN VALVULAR DISEASE, INCLUDING REPRODUCIBILITY GUIDELINES FOR SERIAL STUDIES [J].
CLARK, RD ;
KORCUSKA, K ;
COHN, K .
CIRCULATION, 1980, 62 (03) :564-575
[6]  
Cohen Jacob, 1983, APPLIED MULTIPLE REG
[7]  
CONWAY J, 1988, J HYPERTENS, V6, P111
[8]  
CONWAY J, 1989, J HYPERTENS, V7, pS29
[9]  
CUTTER G R, 1991, Controlled Clinical Trials, V12, p1S
[10]   AMBULATORY BLOOD-PRESSURE RECORDINGS - REPRODUCIBILITY AND UNPREDICTABILITY [J].
DESCOMBES, BJ ;
PORCHET, M ;
WAEBER, B ;
BRUNNER, HR .
HYPERTENSION, 1984, 6 (01) :110-114