PENTACHLOROPHENOL PRECONCENTRATION USING QUINOLIN-8-OL IMMOBILIZED ON CONTROLLED-PORE GLASS AND FLOW SPECTROPHOTOMETRIC DETERMINATION

被引:7
作者
MORENOROMAN, C [1 ]
MONTEROESCOLAR, MR [1 ]
LEONGONZALEZ, ME [1 ]
PEREZARRIBAS, LV [1 ]
POLODIEZ, LM [1 ]
机构
[1] UNIV COMPLUTENSE MADRID,FAC CIENCIAS QUIM,DEPT QUIM ANALIT,E-28040 MADRID,SPAIN
关键词
FLOW SYSTEMS; UV-VISIBLE SPECTROMETRY; PENTACHLOROPHENOL; PRECONCENTRATION; WATERS;
D O I
10.1016/0003-2670(94)80138-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pentachlorophenol preconcentration method using a microcolumn (20 x 2.5 mm i.d.) filled with quinolin-8-ol (oxine) immobilized on controlled-pore glass (CPG) is proposed. The method is based on retention at pH 1 and elution at pH 3 with acetonitrile-water (80 + 20). Maximum retention of pentachlorophenol was 180 mug per gram of oxine-CPG. The breakthrough volume was 100 ml. The good ability for retention and elution allows the flow spectrophotometric determination of microgram amounts of pentachlorophenol. The calibration graph was linear from 4.0 to 25 mug for a sample volume of 100 ml, the repeatability using a single column for 12 mug of pentachlorophenol was 1.2% (R.S.D., n = 4), and the reproducibility between five different microcolumns for the same concentration level was 1.6%. The 3sigma detection limit was 2.5 mug and a preconcentration factor of 250-fold was obtained. Common cations and other phenols do not interfere significantly.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 11 条
[1]   CALCIUM SORPTION BY IMMOBILIZED OXINE AND ITS USE IN DETERMINING FREE CALCIUM-ION CONCENTRATION IN AQUEOUS-SOLUTION [J].
CHOW, PYT ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1988, 60 (15) :1569-1573
[2]   STUDIES ON THE SEPARATION OF ANIONS WITH 8-HYDROXY-QUINOLINIUM ION AS COUNTERION [J].
KUO, MS ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1980, 120 (NOV) :255-266
[3]   SYNTHESIS OF SILICA-IMMOBILIZED 8-QUINOLINOL WITH (AMINOPHENYL)TRIMETHOXYSILANE [J].
MARSHALL, MA ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1983, 55 (13) :2089-2093
[4]   ONLINE MEMBRANE LIQUID-CHROMATOGRAPHIC ANALYZER FOR PENTACHLOROPHENOL AND OTHER TRACE PHENOLS IN WASTE-WATER [J].
MELCHER, RG ;
BAKKE, DW ;
HUGHES, GH .
ANALYTICAL CHEMISTRY, 1992, 64 (19) :2258-2262
[5]  
OBERG T, 1989, CHEMOSPHERE, V9, P337
[6]   LABORATORY EVALUATION OF POLYURETHANE FOAM GRANULAR ADSORBENT SANDWICH CARTRIDGES FOR COLLECTING CHLOROPHENOLS FROM AIR [J].
PATTON, GW ;
MCCONNELL, LL ;
ZARANSKI, MT ;
BIDLEMAN, TF .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2858-2861
[7]   DETERMINATION OF FREE MAGNESIUM-ION CONCENTRATION IN AQUEOUS-SOLUTION USING 8-HYDROXYQUINOLINE IMMOBILIZED ON A NONPOLAR ADSORBENT [J].
PERSAUD, G ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :89-94
[8]  
RODRIQUEZ-GONZALO E, 1992, Analytica Chimica Acta, V259, P37, DOI 10.1016/0003-2670(92)85072-E
[9]   LIQUID-CHROMATOGRAPHY OF PHENOLS ON AN 8-QUINOLINOL SILICA-GEL IRON(III) STATIONARY PHASE [J].
SHAHWAN, GJ ;
JEZOREK, JR .
JOURNAL OF CHROMATOGRAPHY, 1983, 256 (01) :39-48
[10]   INSITU FLUORESCENCE STUDIES OF ALUMINUM ION COMPLEXATION BY 8-HYDROXYQUINOLINE COVALENTLY BOUND TO SILICA [J].
WEAVER, MR ;
HARRIS, JM .
ANALYTICAL CHEMISTRY, 1989, 61 (09) :1001-1010