THE WHOOSH TEST - A CLINICAL-TEST TO CONFIRM CORRECT NEEDLE PLACEMENT IN CAUDAL EPIDURAL INJECTIONS

被引:64
作者
LEWIS, MPN
THOMAS, P
WILSON, LF
MULHOLLAND, RC
机构
[1] Harlow Wood Orthopaedic Hospital, Mansfield, Nottinghamshire, NG18 4TH, Nottingham Road
[2] Harlow Wood Orthopaedic Hospital, Nottinghamshire, NG18 4TH, Nottingham Road, Near Mansfield
[3] Harlow Wood Orthopaedic Hospital, Nottinghamshire, NG18 4TH, Nottingham Road, Near Mansfield
[4] Harlow Wood Orthopaedic Hospital, Mansfield, Nottinghamshire, NG18 4TH, Nottingham Road
关键词
ANESTHETIC TECHNIQUES; REGIONAL; CAUDAL;
D O I
10.1111/j.1365-2044.1992.tb01957.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We describe a previously unreported test to confirm accurate needle placement in caudal epidurals. Of 26 patients undergoing caudal epidural, 19 (73%) had correct needle placement as determined by epidurography. All of these had a positive‘whoosh' test. There were no false positives. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:57 / 58
页数:2
相关论文
共 6 条
[1]   EXTRADURAL CORTICOSTEROID INJECTION IN MANAGEMENT OF LUMBAR NERVE ROOT COMPRESSION [J].
DILKE, TFW ;
BURRY, HC ;
GRAHAME, R .
BRITISH MEDICAL JOURNAL, 1973, 2 (5867) :635-637
[2]   COMPLICATIONS FOLLOWING INTRA-SPINAL INJECTIONS OF STEROIDS - REPORT OF 2 CASES [J].
DOUGHERTY, JH ;
FRASER, RAR .
JOURNAL OF NEUROSURGERY, 1978, 48 (06) :1023-1025
[3]   EPIDURAL STEROID INJECTION - A PROCEDURE IDEALLY PERFORMED WITH FLUOROSCOPIC CONTROL [J].
ELKHOURY, GY ;
EHARA, S ;
WEINSTEIN, JN ;
MONTGOMERY, WJ ;
KATHOL, MH .
RADIOLOGY, 1988, 168 (02) :554-557
[4]   LUMBAR EPIDUROGRAPHY WITH METRIZAMIDE [J].
HATTEN, HP .
RADIOLOGY, 1980, 137 (01) :129-136
[5]  
Sanford H, 1941, RADIOLOGY, V36, P712
[6]  
WHITE AH, 1983, ORTHOP CLIN N AM, V14, P553