IMPROVEMENT OF CORONARY MORPHOLOGY AND BLOOD-FLOW AFTER STENTING - ASSESSMENT BY INTRAVASCULAR ULTRASOUND AND INTRACORONARY DOPPLER

被引:24
作者
GE, JB [1 ]
ERBEL, R [1 ]
ZAMORANO, J [1 ]
HAUDE, M [1 ]
KEARNEY, P [1 ]
GORGE, G [1 ]
MEYER, J [1 ]
机构
[1] UNIV MAINZ, MED CLIN 2, MAINZ, GERMANY
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1995年 / 11卷 / 02期
关键词
INTRAVASCULAR ULTRASOUND; INTRACORONARY DOPPLER; STENTING; PTCA;
D O I
10.1007/BF01844705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) and intracoronary Doppler (ICD) were performed in eight patients (54.3 +/- 6.5 years, 6 male) immediately after PTCA and after stenting. ICD was also performed before PTCA. After PTCA, IVUS has demonstrated intimal rupture in all patients. After stenting, IVUS revealed wall wrapping of the intimal flap with a free lumen in all patients. The lumen diameter was 2.42 +/- 0.55 mm after PTCA and was 2.74 +/- 0.49 mm after stenting (p < 0.001). The cross-sectional area increased from 4.70 +/- 1.99 mm(2) post-PTCA to 6.40 +/- 2.15 mm(2) post-stent (p < 0.005). Coronary flow velocity reserve, calculated by the ratio of mean flow velocity at rest and after intracoronary papaverine administration, increased from 2.05 +/- 1.01 to 2.99 +/- 1.14 after PTCA (p = 0.015); and increased to 4.51 +/- 1.33 after stenting (p < 0.001). The morphological data derived from IVUS correlated with the functional information obtained with ICD. In addition to its established role in bail out situations, stent implantation may be considered when a suboptimal morphological and functional result has been demonstrated.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 29 条
[1]  
Ellis S.G., Roubin G.S., King S.B., Douglas J.S., Shaw R.E., Stertzer S.H., Myler R.K., In-hospital mortality after acute closure after coronary angioplasty: Analysis of risk factors from 8207 procedures, J Am Coll Cardiol, 11, pp. 211-6, (1988)
[2]  
Matthews B.J., Ewels C.J., Kent K.M., Coronary dissection: Predictor of restenosis?, Am Heart J, 115, pp. 547-54, (1988)
[3]  
Sigwart U., Peul J., Mikovitch V., Jofre F., Kappenberger L., Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty, N Eng J Med, 316, pp. 701-6, (1987)
[4]  
De Feyter P.J., DeScheerder I., van den Brand M., Laarman G.J., Suryapranata H., Serruys P.W., Emergency stenting for refractory acute coronary artery occlusion during coronary angioplasty, Am J Cardiol, 66, pp. 1147-50, (1990)
[5]  
Erbel R., Schatz R., Dietz U., Nixdorff U., Haude M., Aichinger S., Pop T., Meyer J., Percutaneous transluminal coronary stent implantation, Z Kardiol, 78, pp. 71-7, (1989)
[6]  
Haude M., Erbel R., Straub U., Dietz U., Schatz R., Meyer J., Results of intracoronary dissection after balloon angioplasty, Am J Cardiol, 67, pp. 691-6, (1991)
[7]  
Nissen S.E., Grines C.L., Gurley J.C., Sublett K., Haynie D., Diaz C., Booth D.C., DeMaria A.N., Application of a new phasedarray ultrasound imaging catheter in the assessment of vascular dimensions: In vivo comparison to cineangiography, Circulation, 81, pp. 660-6, (1990)
[8]  
Davidson C.J., Sheikh K.H., Harrison J.K., Himmelstein S.I., Leithe M.E., Kisslo K.B., Bashore T.M., Intravascular ultrasonography versus digital subtraction angiography: A human in vivo comparison of vessel size and morphology, J Am Coll Cardiol, 16, pp. 633-6, (1990)
[9]  
Ge J., Erbel R., Seidel I., Gorge G., Reichert T., Gerber T., Meyer J., Experimental evaluation of accuracy and safety of intraluminal ultrasound, Z Kardiol, 80, pp. 595-601, (1991)
[10]  
Siegel R.J., Chae J.S., Forrester J.S., Ruiz C.E., Angiography, angioscopy, and ultrasound imaging before and after percutaneous balloon angioplasty, Am Heart J, 120, pp. 1086-90, (1990)