CLINICALLY PRACTICAL LEAD SYSTEMS FOR IMPROVED ELECTROCARDIOGRAPHY - COMPARISON WITH PRECORDIAL GRIDS AND CONVENTIONAL LEAD SYSTEMS

被引:97
作者
LUX, RL [1 ]
BURGESS, MJ [1 ]
WYATT, RF [1 ]
EVANS, AK [1 ]
VINCENT, GM [1 ]
ABILDSKOV, JA [1 ]
机构
[1] UNIV UTAH,NORA ECCLES HARRISON CARDIOVASC RES & TRAINING INST,SALT LAKE CITY,UT 84132
关键词
D O I
10.1161/01.CIR.59.2.356
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of limited leads for estimating total body surface potential distributions was investigated as a practical solution to the problem associated with extensive electrocardiographic sampling used in surface potential mapping. Two practical, limited lead sets of 32 leads each were derived and contrasted to a set of 30 precordial leads similar to those used in ST-segment and QRS mapping for estimating infarcts size, and to a set of nine leads simulating those used in conventional 12-lead examinations. The two arrays, one of which excluded posterior sites for use in recumbent patients, showed little difference in ability to estimate 192 lead measured maps (average rms voltage error of 35 μV and average correlation coefficient of 0.97). The 30- and 9-lead arrays consistently showed twice the voltage (72 μV) and poorer pattern estimation (average correlation coefficient of 0.91) than either of the 32 lead arrays. These findings indicate the need for 20-35 properly located electrodes for accurate total body surface potential estimation. They also show that there is no difference in the ability of a 30-lead precordial array and conventional leads to estimate maps.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 17 条
  • [1] EXPRESSION OF NORMAL VENTRICULAR REPOLARIZATION IN BODY-SURFACE DISTRIBUTION OF T-POTENTIALS
    ABILDSKOV, JA
    BURGESS, MJ
    LUX, RL
    WYATT, R
    VINCENT, GM
    [J]. CIRCULATION, 1976, 54 (06) : 901 - 906
  • [2] UNIDENTIFIED INFORMATION-CONTENT OF ELECTROCARDIOGRAM
    ABILDSKOV, JA
    BURGESS, MJ
    URIE, PM
    LUX, RL
    WYATT, RF
    [J]. CIRCULATION RESEARCH, 1977, 40 (01) : 3 - 7
  • [3] Ambroggi L. D., 1976, CIRCULATION, V54, P251
  • [4] SELECTION OF NUMBER AND POSITIONS OF MEASURING LOCATIONS FOR ELECTROCARDIOGRAPHY
    BARR, RC
    SPACH, MS
    HERMANGI.GS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (02) : 125 - &
  • [5] GENESIS OF BODY SURFACE POTENTIALS IN VARYING TYPES OF RIGHT VENTRICULAR HYPERTROPHY
    BLUMENSCHEIN, SD
    SPACH, MS
    BOINEAU, JP
    BARR, RC
    GALLIE, TM
    WALLACE, AG
    EBERT, PA
    [J]. CIRCULATION, 1968, 38 (05) : 917 - +
  • [6] BURGESS MJ, CIRC RES
  • [7] HOLT JH, 1969, CIRCULATION, V40, P697, DOI 10.1161/01.CIR.40.5.697
  • [8] A STUDY OF HUMAN HEART AS A MULTIPLE DIPOLE ELECTRICAL SOURCE .3. DIAGNOSIS AND QUANTITATION OF RIGHT VENTRICULAR HYPERTROPHY
    HOLT, JH
    BARNARD, ACL
    LYNN, MS
    KRAMER, JO
    [J]. CIRCULATION, 1969, 40 (05) : 711 - &
  • [9] KORNREICH F, 1976, VECTORCARDIOGRAPHY, P171
  • [10] LIMITED LEAD SELECTION FOR ESTIMATION OF BODY-SURFACE POTENTIAL MAPS IN ELECTROCARDIOGRAPHY
    LUX, RL
    SMITH, CR
    WYATT, RF
    ABILDSKOV, JA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1978, 25 (03) : 270 - 276