LEFT-VENTRICULAR VOLUME AND ENDOCARDIAL SURFACE-AREA BY 3-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND NUCLEAR-MAGNETIC-RESONANCE IMAGING IN NORMAL SUBJECTS

被引:143
作者
GOPAL, AS [1 ]
KELLER, AM [1 ]
RIGLING, R [1 ]
KING, DL [1 ]
KING, DL [1 ]
机构
[1] DANBURY HOSP,DIV CARDIOL,DANBURY,CT 06810
关键词
D O I
10.1016/0735-1097(93)90842-O
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We evaluated a three-dimensional echocardiographic method for ventricular volume and surface area determination that uses polyhedral surface reconstruction. Six to eight nonparallel, unequally spaced, nonintersecting short-axis planes were positioned with a line of intersection display to overcome limitations associated with two-dimensional echocardiography. Background. Two-dimensional echocardiographic methods of ventricular volume and surface area determination are limited by assumptions about ventricular shape and image plane position. Methods. Left ventricular end-diastolic and end-systolic volumes and endocardial surface areas determined by three-dimensional echocardiography and nuclear magnetic resonance (NMR) imaging were compared in 15 normal subjects (7 men, 8 women, aged 23 to 41 years, body surface area 1.38 to 2.17 m2). Ten of these subjects also underwent two-dimensional echocardiography; and end-diastolic and end-systolic volumes were determined by the apical biplane summation of discs method and compared with results of NMR imaging. Results. Interobserver variability was 5% to 8% for three-dimensional echocardiography and 6% to 9% for NMR imaging. Both methods were in close agreement on end-diastolic volume (r = 0.92, SEE = 6.99 ml) and end-systolic volume (r = 0.81, SEE = 4.01 ml) and on end-diastolic surface area (r = 0.84, SEE = 8.25 cm2) and end-systolic surface area (r = 0.84, SEE = 4.89 CM2) . Three-dimensional echocardiography and NMR imaging correlated significantly better for end-diastolic volume (r = 0.90, SEE = 7.0 ml) and end-systolic volume (r = 0.88, SEE = 3.1 ml) than did two-dimensional echocardiography and NMR imaging (r = 0.48, SEE = 20.5 ml for end-diastolic volume; r = 0.70, SEE = 5.6 ml for end-systolic volume). Conclusions. Three-dimensional echocardiography is an in vivo method of measuring left ventricular end-diastolic and end-systolic volumes and endocardial surface area with results comparable to those of NMR imaging. Additionally, three-dimensional echocardiography is superior to the two-dimensional echocardiographic apical biplane summation method because the technique eliminates geometric assumptions and image plane positioning error.
引用
收藏
页码:258 / 270
页数:13
相关论文
共 53 条
[1]   EVALUATION OF A 3-DIMENSIONAL RECONSTRUCTION TO COMPUTE LEFT-VENTRICULAR VOLUME AND MASS [J].
ARIET, M ;
GEISER, EA ;
LUPKIEWICZ, SM ;
CONETTA, DA ;
CONTI, CR .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (03) :415-420
[2]  
COOK L T, 1981, Automedica (London), V4, P13
[3]   AN ALGORITHM FOR VOLUME ESTIMATION BASED ON POLYHEDRAL APPROXIMATION [J].
COOK, LT ;
COOK, PN ;
LEE, KR ;
BATNITZKY, S ;
WONG, BYS ;
FRITZ, SL ;
OPHIR, J ;
DWYER, SJ ;
BIGONGIARI, LR ;
TEMPLETON, AW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (09) :493-500
[4]   SYSTEM FOR ULTRASONICALLY IMAGING HUMAN HEART IN 3 DIMENSIONS [J].
DEKKER, DL ;
PIZIALI, RL ;
DONG, E .
COMPUTERS AND BIOMEDICAL RESEARCH, 1974, 7 (06) :544-553
[5]   USEFULNESS AND LIMITATIONS OF RADIOGRAPHIC METHODS FOR DETERMINING LEFT VENTRICULAR VOLUME [J].
DODGE, HT ;
SANDLER, H ;
BAXLEY, WA ;
HAWLEY, RR .
AMERICAN JOURNAL OF CARDIOLOGY, 1966, 18 (01) :10-&
[6]   ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
ERBEL, R ;
SCHWEIZER, P ;
LAMBERTZ, H ;
HENN, G ;
MEYER, J ;
KREBS, W ;
EFFERT, S .
CIRCULATION, 1983, 67 (01) :205-215
[7]   ASSESSMENT OF LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES BY REAL-TIME, 2-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON OF CINEANGIOGRAPHIC AND RADIONUCLIDE TECHNIQUES [J].
FOLLAND, ED ;
PARISI, AF ;
MOYNIHAN, PF ;
JONES, DR ;
FELDMAN, CL ;
TOW, DE .
CIRCULATION, 1979, 60 (04) :760-766
[8]   DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE INTACT HUMAN LEFT-VENTRICLE - TECHNIQUE AND INITIAL OBSERVATIONS IN PATIENTS [J].
GEISER, EA ;
ARIET, M ;
CONETTA, DA ;
LUPKIEWICZ, SM ;
CHRISTIE, LG ;
CONTI, CR .
AMERICAN HEART JOURNAL, 1982, 103 (06) :1056-1065
[9]   3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD [J].
GHOSH, A ;
NANDA, NC ;
MAURER, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) :655-661
[10]  
Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115