ELECTRICAL-PROPERTIES OF METALLIC ELECTRODES

被引:79
作者
RAGHEB, T
GEDDES, LA
机构
[1] The William A. Hillenbrand Center for Biomedical Engineering, Purdue University, West Lafayette, 47907, IN
关键词
Current density linearity limit; Electrode capacitance; Electrode resistance; Electrode-electrolyte interface; Electrodes; Warburg model;
D O I
10.1007/BF02441775
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The series equivalent resistance R and capacitance C of metal/saline electrode/electrolyte interfaces were measured as a function of frequency (100 Hz-20k Hz) and current density (0·25 to 1000 A m-2) for eight typical electrode metals. For each of the metals tested, R decreased and C increased as the current density was increased above a critical value (with the exception of silver and MP35N at frequencies above 1 kHz for which R increased and C decreased slightly). With the exception of copper, the current density linearity limit (for 10 per cent decrease in R or 10 per cent increase in C) increased with increasing frequency and, in most cases, the current density linearity limit for 10 per cent increase in C was slightly less than that for 10 per cent decrease in R. Among the metals tested, copper and aluminium had the lowest current carrying capability and rhodium had the highest current-carrying capability. The current carrying capabilities of 316 SS, platinum, silver and MP35N, were intermediate and similar. With increasing current density, an increase in the electrode/electrolyte capacitance was the most sensitive indicator of the current-carrying linearity limit. © 1990 IFMBE.
引用
收藏
页码:182 / 186
页数:5
相关论文
共 15 条
[1]  
[Anonymous], 1963, PHYS TECHNIQUES BIOL, DOI DOI 10.1002/JCP.1030660505
[2]   CHARACTERISTICS OF METAL-TISSUE INTERFACE OF STIMULATION ELECTRODES [J].
DYMOND, AM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (04) :274-280
[3]  
DYMOND AM, 1970, 7TH P ANN ROCK MOUNT, P141
[4]  
Fricke H, 1932, PHILOS MAGAZINE J SC, V14, P310
[5]  
Geddes L. A., 1972, ELECTRODES MEASUREME
[6]   THE RECTIFICATION PROPERTIES OF AN ELECTRODE ELECTROLYTE INTERFACE OPERATED AT HIGH SINUSOIDAL CURRENT-DENSITY [J].
GEDDES, LA ;
FOSTER, KS ;
REILLY, J ;
VOORHEES, WD ;
BOURLAND, JD ;
RAGHEB, T ;
FEARNOT, NE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (09) :669-672
[7]   IMPEDANCE OF STAINLESS-STEEL ELECTRODES [J].
GEDDES, LA ;
DACOSTA, CP ;
WISE, G .
MEDICAL & BIOLOGICAL ENGINEERING, 1971, 9 (05) :511-&
[8]  
GEDDES LA, 1973, CHEM INSTRUM, V4, P157
[9]   NONLINEARITY OF CARDIAC PACEMAKER ELECTRODES [J].
JARON, D ;
BRILLER, SA ;
SCHWAN, HP ;
GESELOWITZ, DB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1969, BM16 (02) :132-+
[10]   LINEAR AND NON-LINEAR PROPERTIES OF PLATINUM-ELECTRODE POLARIZATION .1. FREQUENCY-DEPENDENCE AT VERY LOW-FREQUENCIES [J].
ONARAL, B ;
SCHWAN, HP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (03) :299-306