NEGATIVE-ION MASS-SPECTROMETRY IN A COMMERCIAL GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETER SYSTEM

被引:12
作者
CATINELLA, S
TRALDI, P
JIANG, XW
LONDRY, FA
MORRISON, RJS
MARCH, RE
GREGOIRE, S
MATHURIN, JC
TABET, JC
机构
[1] TRENT UNIV,DEPT CHEM,PETERBOROUGH,ON K9J 7B8,CANADA
[2] CNR,I-35020 PADUA,ITALY
[3] UNIV PARIS 06,F-75007 PARIS,FRANCE
[4] MONASH UNIV,DEPT CHEM,MELBOURNE,VIC 3168,AUSTRALIA
关键词
D O I
10.1002/rcm.1290091316
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Commercial gas chromatography quadrupole ion-trap mass spectrometer (GC/ITMS) instruments have been used in a novel way for the study of negative ions formed from perfluorotributyl-amine and polychlorinated biphenyl compounds, Negative ions, formed during a normal electron impact ionization period in which 70 eV electrons were used, were isolated in an ion trap by the application of a negative DC voltage to the ring electrode that caused all positive ions to be ejected from the ion trap; in the subsequent analytical scan, negatives ions were detected with an electron multiplier biased normally so as to detect positive ions, The major negative-ion species detected from FC-43 were m/z 252 to m/z 633; 34 other negative-ion species were detected also, though in low abundance, The observed negative-ion mass range extended from m/z 252 to milt 633, The signal-to-noise ratio of negative-ion mass spectra was enhanced by operation of the GC/MS instrument in GC mode and averaging the mass spectra acquired, In an examination of 3 hexachlorobiphenyl compounds, the molecular anion cluster around m/z 360 for the non-ortho-substituted congener 169 was observed with a signal-to-noise ratio of ca, 20 for 90 pg injected on column: the response for congener 169 was greater than that for congener 156 (mono ortho-substituted) which, in turn, was greater than that for congener 153 (di-ortho-substituted).
引用
收藏
页码:1302 / 1309
页数:8
相关论文
共 20 条
[1]  
ARMITAGE MA, 1979, THESIS TRENT U PETER
[2]   DERIVATIONS OF FIELD EQUATIONS AND STABILITY PARAMETERS FOR 3 OPERATING MODES OF 3-DIMENSIONAL QUADRUPOLE [J].
BONNER, RF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1977, 23 (04) :249-257
[3]  
HUGHES RJ, 1980, THESIS TRENT U PETER
[4]   ELECTRON-CAPTURE NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
HUNT, DF ;
CROW, FW .
ANALYTICAL CHEMISTRY, 1978, 50 (13) :1781-1784
[5]  
INGHRAM MG, 1953, CIRCULATION, V522, P257
[6]  
JIANG XPC, UNPUB
[7]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS BY QUADRUPOLE ION-TRAP MASS-SPECTROMETRY .2. COMPARISON OF MASS-SPECTROMETRIC DETECTION USING ELECTRON-IMPACT AND SELECTED-ION CHEMICAL-IONIZATION WITH ELECTRON-CAPTURE DETECTION [J].
LAUSEVIC, M ;
JIANG, X ;
METCALFE, CD ;
MARCH, RE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) :927-936
[8]   RESONANCE EXCITATION OF IONS STORED IN A QUADRUPOLE ION TRAP .2. FURTHER SIMULATION STUDIES [J].
MARCH, RE ;
MCMAHON, AW ;
ALLINSON, ET ;
LONDRY, FA ;
ALFRED, RL ;
TODD, JFJ ;
VEDEL, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 99 (1-2) :109-124
[9]  
MARCH RE, 1984, SPECTROSC INT J, V3, P17
[10]  
MARCH RE, 1989, QUADRUPOLE STORAGE M, V102