DOPPLER SIGNAL QUANTITATION IN RENAL-ALLOGRAFTS - COMPARISON IN NORMAL AND REJECTING TRANSPLANTS, WITH PATHOLOGICAL CORRELATION

被引:152
作者
RIGSBY, CM
BURNS, PN
WELTIN, GG
CHEN, B
BIA, M
TAYLOR, KJW
机构
[1] YALE UNIV, SCH MED, DEPT DIAGNOST RADIOL, 333 CEDAR ST, NEW HAVEN, CT 06510 USA
[2] YALE UNIV, SCH MED, DEPT NEPHROL, NEW HAVEN, CT 06510 USA
关键词
D O I
10.1148/radiology.162.1.3538151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative duplex Doppler sonography was performed in 55 renal transplant patients during 54 independent episodes of acute rejection, three episodes of chronic rejection, three episodes of acute tubular necrosis (ATN), and 23 occasions of normal graft function. Doppler signals were obtained from four arterial sites in each kidney. Nine patients, in whom signals were absent, were subsequently shown at nephrectomy to have absence of perfusion resulting from severe acute vascular rejection. In each patient with graft dysfunction, biopsy or nephrectomy was performed within 24 hours of the Doppler study. Arterial Doppler signals were quantified using a pulsatility index (PI). Acute rejection produced a significantly higher PI at each arterial site. Receiver-operator characteristics suggest that signals obtained from the segmental arteries are most sensitive to these changes. With a threshold PI of 1.5, the sensitivity of this technique for detection of acute renal allograft rejection is 75%; the specificity is 90%. In acute vascular rejection, the same PI yields a sensitivity of 79% and specificity of 90%. With a cutoff PI of 1.8, a specificity of 100% can be achieved.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 8 条
  • [1] PREDICTABILITY OF RENAL-ALLOGRAFT PROGNOSIS DURING REJECTION CRISIS BY ULTRASONIC DOPPLER FLOW TECHNIQUE
    ARIMA, M
    TAKAHARA, S
    IHARA, H
    ICHIKAWA, Y
    ISHIBASHI, M
    SAGAWA, S
    NAGANO, S
    TAKAHA, M
    SONODA, T
    [J]. UROLOGY, 1982, 19 (04) : 389 - 394
  • [2] ANALYSIS OF THE ARTERIAL BLOOD-FLOW PATTERNS OF NORMAL AND ALLOGRAFTED KIDNEYS BY THE DIRECTIONAL ULTRASONIC DOPPLER TECHNIQUE
    ARIMA, M
    ISHIBASHI, M
    USAMI, M
    SAGAWA, S
    MIZUTANI, S
    SONODA, T
    ICHIKAWA, S
    IHARA, H
    NAGANO, S
    [J]. JOURNAL OF UROLOGY, 1979, 122 (05) : 587 - 591
  • [3] EVALUATION OF RENAL-TRANSPLANTS WITH PULSED DOPPLER DUPLEX SONOGRAPHY
    BERLAND, LL
    LAWSON, TL
    ADAMS, MB
    MELROSE, BL
    FOLEY, WD
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1982, 1 (06) : 215 - 222
  • [4] THE RELATIONSHIP BETWEEN ULTRASONIC PULSATILITY INDEX AND PROXIMAL ARTERIAL-STENOSIS IN A CANINE MODEL
    EVANS, DH
    BARRIE, WW
    ASHER, MJ
    BENTLEY, S
    BELL, PRF
    [J]. CIRCULATION RESEARCH, 1980, 46 (04) : 470 - 475
  • [5] RENAL-ARTERY FLOW VELOCITY ANALYSIS - A SENSITIVE MEASURE OF EXPERIMENTAL AND CLINICAL RENOVASCULAR RESISTANCE
    NORRIS, CS
    BARNES, RW
    [J]. JOURNAL OF SURGICAL RESEARCH, 1984, 36 (03) : 230 - 236
  • [6] RENAL-ALLOGRAFTS IN ACUTE REJECTION - EVALUATION USING DUPLEX SONOGRAPHY
    RIGSBY, CM
    TAYLOR, KJW
    WELTIN, G
    BURNS, PN
    BIA, M
    PRINCENTHAL, RA
    KASHGARIAN, M
    FLYE, MW
    [J]. RADIOLOGY, 1986, 158 (02) : 375 - 378
  • [7] DUPLEX DOPPLER SCANNING IN THE PELVIS AND ABDOMEN
    TAYLOR, KJW
    BURNS, PN
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (04) : 643 - 658
  • [8] ZOLLINGER HU, 1978, RENAL PATHOLOGY BIOP, P564