A LOW-NOISE HIGHLY INTEGRATED BOLOMETER ARRAY FOR ABSOLUTE MEASUREMENT OF VUV AND SOFT X-RADIATION

被引:139
作者
MAST, KF
VALLET, JC
ANDELFINGER, C
BETZLER, P
KRAUS, H
SCHRAMM, G
机构
[1] Max-Planck-Institut für Plasmaphysik, EURATOM-IPP Association
关键词
D O I
10.1063/1.1142078
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new low noise miniaturized multichannel bolometer module for absolute measurements in the VUV and soft x spectral ranges is described. Highly integrated four-channel modules (2x3.3x1.5 cm3) each comprising four independent ac-excited (50 kHz) metal resistor bolometer bridges were successfully tested on a large tokamak (Tore Supra in Cadarache) and on an electron synchrotron (BESSY in Berlin). The bolometer system features a linear response to the absorbed radiation power, a low detection limit (less-than-or-equal-to 1.0 x 10(-6) W cm-2 on Tore Supra with an integration time of tau-int = 10 x 10(-3) S) and a low NEP (less-than-or-equal-to 10 x 10(-9) W on BESSY). The thermal cross-talk between adjacent detectors is negligible (< 0.003) and a low thermal drift DELTA-U(Br)/DELTA-T < 10(-4) V-degrees-C-1 is achieved. It can be operated at a maximum temperature of 150-degrees-C, at high magnetic fields (tested up to B = 4.5 T in the laboratory) and survives high nuclear radiation doses. The system offers the possibility of detecting low-power VUV and soft x-radiation with sampling rates of up to 10 kHz on plasma machines and of absolutely calibrating VUV and soft x instruments. Effective suppression of electric, thermal and nuclear radiation interferences is characteristic of the bolometer system. Strain gauge effects, which could affect the behavior of the bolometers at high magnetic fields, are suppressed by the ac-excitation technique.
引用
收藏
页码:744 / 750
页数:7
相关论文
共 13 条
  • [1] ANDELFINGER C, 1988, 15TH P SOFT UTR, P374
  • [2] BETZLER P, COMMUNICATION
  • [3] MEASUREMENT OF ENERGY-BALANCE IN ATC TOKAMAK
    HSUAN, H
    BOL, K
    ELLIS, RA
    [J]. NUCLEAR FUSION, 1975, 15 (04) : 657 - 661
  • [4] JACKEL HJ, 1987, 14TH P EUR C CONTR F, P718
  • [5] JACKEL JH, 1988, IPP2291 REP
  • [6] BOLOMETRIC DIAGNOSTICS IN JET
    MAST, KF
    KRAUSE, H
    BEHRINGER, K
    BULLIARD, A
    MAGYAR, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05) : 969 - 971
  • [7] MAST KF, 1989, IPP1247 MPI PLASM RE
  • [8] MULLER ER, 1984, J APPL PHYS, V55, P2635, DOI 10.1063/1.333272
  • [9] MULLER ER, 1985, IPP1224 REP
  • [10] SCHEUERER R, 1989, THESIS TU MUNCHEN