THEORETICAL-STUDY OF PERMSELECTIVE LAYERS ON AMPEROMETRIC ELECTRODES IN FLOWING STREAMS

被引:6
作者
BREEN, W
CASSIDY, JF
LYONS, MEG
机构
[1] DUBLIN INST TECHNOL,DEPT CHEM,KEVIN ST,DUBLIN 8,IRELAND
[2] UNIV DUBLIN TRINITY COLL,PHYS CHEM LAB,DUBLIN 2,IRELAND
关键词
D O I
10.1021/ac00020a013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A model consisting of the response of a porous permselective coating on an electrode in an amperometric configuration is solved for two types of concentration profile impinging on the polymer solution interface. A Gaussian concentration profile and a Poisson concentration profile are examined, since both profiles typically arise in both flow injection analysis (FIA) and high-performance liquid chromatography (HPLC). Analytical expressions for current and for concentration profiles within the layer are derived. Working curves are presented that allow estimation of peak height decrease, peak broadening, lag time, and diffusional talling due to coating the amperometric detector with a permselective layer. It is possible by using these equations and working curves to estimate the diffusion coefficient of substrate through the layer and to design layers which minimize lag time and peak talling and optimize peak height.
引用
收藏
页码:2263 / 2268
页数:6
相关论文
共 29 条
[1]  
BETTERIDGE D, 1978, ANAL CHEM, V50, pA832, DOI 10.1021/ac50031a001
[2]  
Boyce W. E., 2012, ELEMENTARY DIFFERENT, V10th ed.
[3]   IMMOBILIZATION BARRIER EFFECTS ON THE DYNAMIC-RESPONSE CHARACTERISTICS OF POTENTIOMETRIC ADENOSINE-DEAMINASE ENZYME ELECTRODES [J].
BRADLEY, CR ;
RECHNITZ, GA .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1401-1404
[4]   DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY AT MERCURY POLY(4-VINYLPYRIDINE) COATINGS ON GLASSY-CARBON ELECTRODES [J].
CASSIDY, J ;
LOWNEY, C .
ANALYTICA CHIMICA ACTA, 1990, 234 (02) :479-482
[5]   USE OF MERCURY CONTAINING ZEOLITE-A LAYERS ON GLASSY-CARBON FOR DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
CASSIDY, J ;
ODONOGHUE, E ;
BREEN, W .
ANALYST, 1989, 114 (11) :1509-1510
[6]   AMPEROMETRIC RESPONSE OF ELECTRODES WITH POROUS COATINGS TO GAUSSIAN CONCENTRATION PROFILES IN FLOWING STREAMS [J].
CASSIDY, J ;
BREEN, W ;
LYONS, MEG .
ELECTROANALYSIS, 1991, 3 (4-5) :293-297
[7]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[8]   DIFFUSIONAL DISTORTION IN THE MONITORING OF DYNAMIC EVENTS [J].
ENGSTROM, RC ;
WIGHTMAN, RM ;
KRISTENSEN, EW .
ANALYTICAL CHEMISTRY, 1988, 60 (07) :652-656
[9]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[10]   PARALLEL DUAL-ELECTRODE DETECTION BASED ON SIZE EXCLUSION FOR LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY [J].
HUTCHINSKUMAR, LD ;
WANG, J ;
TUZHI, P .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1019-1023