ELEVATED CONCENTRATIONS OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS IN PLASMA - AN EARLY MARKER OF GRAM-NEGATIVE BACTEREMIA

被引:34
作者
DEITCHER, SR [1 ]
EISENBERG, PR [1 ]
机构
[1] WASHINGTON UNIV,DIV CARDIOVASC,4940 PARKVIEW PL,ST LOUIS,MO 63110
关键词
D O I
10.1378/chest.103.4.1107
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Because coagulant and fibrinolytic activity are increased by endotoxin, we hypothesized that concentrations of cross-linked fibrin degradation products, sensitive markers of plasmin activity, would be increased in patients with Gram-negative bacteremia. Patients and methods: Cross-linked fibrin degradation products were measured with an enzyme-linked immunosorbent assay (ELISA) based on a monoclonal antibody specific for cross-linked fibrin degradation products, and with a novel, semiquantitative hemagglutination assay based on the same antibody coupled to FAB' fragments from a monoclonal antibody against a universal red blood cell antigen. Blood samples were obtained from 100 consecutive emergency department patients evaluated for sepsis. Results: Blood cultures were positive in 21 percent of the patients, 75 percent (12/21) with Gram-negative organisms. Elevations of cross-linked fibrin degradation products (normal < 200 ng/ml) were measured by ELISA in all patients (12/12) with Gram-negative bacteremia. The hemagglutination assay was positive in ten of these. Detectable increases in fibrinolytic activity occurred in all patients with Gram-negative bacteremia, even in the absence of clinical signs or laboratory evidence of sepsis or disseminated intravascular coagulation. The ELISA and hemagglutination assay had negative predictive values for Gram-negative bacteremia of 100 percent and 96 percent, respectively. Conclusion: Elevation of cross-linked fibrin degradation products consistent with increased fibrinolytic activity occurs in all patients with Gram-negative bacteremia. Accordingly, the lack of elevation may be clinically useful in identifying patients less likely to have Gram-negative bacteremia.
引用
收藏
页码:1107 / 1112
页数:6
相关论文
共 29 条
  • [1] PREDICTING BACTEREMIA IN HOSPITALIZED-PATIENTS - A PROSPECTIVELY VALIDATED MODEL
    BATES, DW
    COOK, EF
    GOLDMAN, L
    LEE, TH
    [J]. ANNALS OF INTERNAL MEDICINE, 1990, 113 (07) : 495 - 500
  • [2] PASSIVE-IMMUNIZATION AGAINST CACHECTIN TUMOR NECROSIS FACTOR PROTECTS MICE FROM LETHAL EFFECT OF ENDOTOXIN
    BEUTLER, B
    MILSARK, IW
    CERAMI, AC
    [J]. SCIENCE, 1985, 229 (4716) : 869 - 871
  • [3] THE PATHOGENESIS OF SEPSIS
    BONE, RC
    [J]. ANNALS OF INTERNAL MEDICINE, 1991, 115 (06) : 457 - 469
  • [4] MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM
    BOUNAMEAUX, H
    CIRAFICI, P
    DEMOERLOOSE, P
    SCHNEIDER, PA
    SLOSMAN, D
    REBER, G
    UNGER, PF
    [J]. LANCET, 1991, 337 (8735) : 196 - 200
  • [5] MEASUREMENT OF PLASMA D-DIMER FOR DIAGNOSIS OF DEEP VENOUS THROMBOSIS
    BOUNAMEAUX, H
    SCHNEIDER, PA
    REBER, G
    DEMOERLOOSE, P
    KRAHENBUHL, B
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (01) : 82 - 85
  • [6] DIAGNOSIS OF DISSEMINATED INTRAVASCULAR COAGULATION - ROLE OF D-DIMER
    CARR, JM
    MCKINNEY, M
    MCDONAGH, J
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (03) : 280 - 287
  • [7] ENDOTOXEMIA IN HUMAN SEPTIC SHOCK
    DANNER, RL
    ELIN, RJ
    HOSSEINI, JM
    WESLEY, RA
    REILLY, JM
    PARILLO, JE
    [J]. CHEST, 1991, 99 (01) : 169 - 175
  • [8] INTERLEUKIN-1
    DINARELLO, CA
    [J]. REVIEWS OF INFECTIOUS DISEASES, 1984, 6 (01): : 51 - 95
  • [9] RELATIONSHIP BETWEEN ELEVATED PLASMA-LEVELS OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS (XL-FDP) AND THE CLINICAL PRESENTATION OF PATIENTS WITH MYOCARDIAL-INFARCTION
    EISENBERG, PR
    SHERMAN, LA
    PEREZ, J
    JAFFE, AS
    [J]. THROMBOSIS RESEARCH, 1987, 46 (01) : 109 - 120
  • [10] LACK OF CLINICAL USEFULNESS OF LIMULUS TEST IN DIAGNOSIS OF ENDOTOXEMIA
    ELIN, RJ
    ROBINSON, RA
    LEVINE, AS
    WOLFF, SM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1975, 293 (11) : 521 - 524