EVALUATION OF PHOSPHOLIPIDIC SURFACE-COATINGS EX-VIVO

被引:26
作者
VONSEGESSER, LK
TONZ, M
LESKOSEK, B
TURINA, M
机构
[1] Clinic for Cardiovascular Surgery, University Hospital, CH-8091 Zurich
关键词
THROMBORESISTANCE; BIOCOMPATIBILITY; BLOOD EXPOSED SURFACES; PERFUSION; PHOSPHOLIPIDS;
D O I
10.1177/039139889401700507
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate the thromboresistant properties of phospholipidic surface coatings mimicking the lipid surface of blood cells, we studied four different types of phospholipids bound onto PVC tubings in comparison to uncoated as well as heparin bonded controls. The samples analyzed included diacetylenic phospholipid coated as a monomeric treatment (A), diacetylenic phospholipid polymerised prior to being coated (B), and two types of polymeric phospholipids made using methacrylate containing monomers (C and D). A bovine (bodyweight 67 +/- 3 kg) left heart bypass model (pump flow 3.2 +/- 0.1 l/min) was selected and the surfaces were exposed to the blood stream up to 360 min without systemic heparinization, Thereafter another set of samples was exposed to stagnant blood over 20 min. Besides hemodynamic, hematologic and biochemical analyses, the macroscopic appearance of 119 blood exposed surface samples was graded semiquantitatively on a scale of 0 to 10: no macroscopic deposits = grade 0, 1 spot (1 mm diameter grade 1, 2 spots = grade 2, 5 or more spots = grade 5, up to 10% of the surface covered with clots = grade 6, 100% covered = grade 10 (P<0.05=*): mean grade of deposit was 0.0 +/- 0.0 for segments perfused and 0.0 +/- 0.0 for segments exposed to stagnant blood with surfaces exposing to the blood either heparin, phopholipid A, or phospholipid B (NS). Phospholipids C and D were graded 0.0 +/- 0.0 if perfused and 0.7 +/- 1.2 if exposed to stagnant blood. Uncoated PVC control tubings however were graded 0.2 +/- 0.8 for segments perfused and 2.7 +/- 3.0 for segments exposed to stagnat blood (p<0.05 in comparison to all surfaces coated with phospholipids or heparin if perfused and if exposed to stagnant blood). Hence phospholipidic surface coatings expose significant antithrombotic properties which out perform todays standard for tubings in clinical perfusion (uncoated PVC).
引用
收藏
页码:294 / 300
页数:7
相关论文
共 13 条
[1]   TREATMENT OF ACUTE RESPIRATORY-FAILURE BY EXTRACORPOREAL CARBON-DIOXIDE ELIMINATION PERFORMED WITH A SURFACE HEPARINIZED ARTIFICIAL LUNG [J].
BINDSLEV, L ;
EKLUND, J ;
NORLANDER, O ;
SWEDENBORG, J ;
OLSSON, P ;
NILSSON, E ;
LARM, O ;
GOUDA, I ;
MALMBERG, A ;
SCHOLANDER, E .
ANESTHESIOLOGY, 1987, 67 (01) :117-120
[2]  
Chapman D, 1992, CHEM BRIT, V3, P253
[3]  
CUKINGNAN RA, 1978, J THORAC CARDIOV SUR, V75, P227
[4]  
GOTT VL, 1963, SCIENCE, V142, P1297, DOI 10.1126/science.142.3597.1297
[5]   A NEW NON-THROMBOGENIC SURFACE PREPARED BY SELECTIVE COVALENT BINDING OF HEPARIN VIA A MODIFIED REDUCING TERMINAL RESIDUE [J].
LARM, O ;
LARSSON, R ;
OLSSON, P .
BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1983, 11 (2-3) :161-173
[6]  
NOSSEL HL, 1976, NEW ENGL J MED, V295, P428
[7]  
von Segesser L K, 1990, Semin Thorac Cardiovasc Surg, V2, P373
[8]  
von Segesser L K, 1993, ASAIO J, V39, P43, DOI 10.1097/00002480-199301000-00010
[9]   EXTENDED (29 DAYS) USE OF INTRAVASCULAR GAS EXCHANGER [J].
VONSEGESSER, LK ;
SCHAFFNER, A ;
STOCKER, R ;
LACHAT, M ;
SPEICH, R ;
BAUMANN, PC ;
TURINA, M .
LANCET, 1992, 339 (8808) :1536-1536
[10]  
VONSEGESSER LK, 1992, J THORAC CARDIOV SUR, V103, P790