EFFECTS OF NONINVASIVE AMBULATORY BLOOD-PRESSURE MEASURING DEVICES ON BLOOD-PRESSURE

被引:15
作者
BRIGDEN, G [1 ]
BROADHURST, P [1 ]
CASHMAN, P [1 ]
RAFTERY, EB [1 ]
机构
[1] CLIN RES CTR,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
D O I
10.1016/0002-9149(90)91181-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It is well recognized that the act of blood pressure (BP) measurement may influence the level of BP.1 This "cuff response" is attributed to an alerting reaction; it does not decrease with repeated measurement, and is worse in the presence of a doctor than in the presence of a nurse.2 This suggests that the major component of the reaction is not discomfort from inflation of the cuff, and this is supported by the fact that BP usually increases before the cuff is applied. These observations have led to the assumption that ambulatory cuff BP devices do not provoke such effects. This is implicit in the high reproducibility of measurements in groups of subjects that has been observed with some modern machines,3 although this could simply reflect the reproducibility of the alerting response. This issue has only been addressed in subjects confined to bed for relatively brief periods.4 No account has been taken of the possibility of effects on patients trying to sleep at night, or of the overall impact of wearing such devices. Ambulatory BP monitors are coming into wide use for the assessment of hypertensive subjects before and after treatment. This follows observations that ambulatory measurements are better prognostic indicators than casual readings.5 This study tests the hypothesis that wearing an ambulatory cuff BP monitor might, in itself, alter BP by increasing discomfort, influencing activity or sleep patterns, or by promoting an alerting response. © 1990.
引用
收藏
页码:1396 / 1398
页数:3
相关论文
共 10 条
  • [1] CASADEI R, 1988, J HYPERTENS, V6, P797
  • [2] CONWAY J, 1988, J HYPERTENS, V6, P111
  • [3] AN EVALUATION OF THE AVIONICS PRESSUROMETER-III 1978 AT HOME AND IN HOSPITAL
    GOULD, BA
    HORNUNG, RS
    CASHMAN, PMM
    ALTMAN, D
    RAFTERY, EB
    [J]. CLINICAL CARDIOLOGY, 1986, 9 (07) : 335 - 343
  • [4] ASSESSMENT OF THE ACCURACY AND ROLE OF SELF-RECORDED BLOOD PRESSURES IN THE MANAGEMENT OF HYPERTENSION
    GOULD, BA
    KIESO, HA
    HORNUNG, R
    ALTMAN, DG
    CASHMAN, PMM
    RAFTERY, EB
    [J]. BRITISH MEDICAL JOURNAL, 1982, 285 (6356) : 1691 - 1694
  • [5] HEMODYNAMIC-ALTERATIONS TRIGGERED BY BLOOD-PRESSURE ASSESSMENTS BY THE DOCTOR
    MANCIA, G
    BERTINIERI, G
    GRASSI, G
    POMIDOSSI, G
    PARATI, G
    GREGORINI, L
    FERRARI, A
    ZANCHETTI, A
    [J]. CLINICAL SCIENCE, 1982, 63 : S387 - S389
  • [6] ALERTING REACTION AND RISE IN BLOOD-PRESSURE DURING MEASUREMENT BY PHYSICIAN AND NURSE
    MANCIA, G
    PARATI, G
    POMIDOSSI, G
    GRASSI, G
    CASADEI, R
    ZANCHETTI, A
    [J]. HYPERTENSION, 1987, 9 (02) : 209 - 215
  • [7] NEW SYSTEM FOR RECORDING AMBULATORY BLOOD-PRESSURE IN MAN
    MILLARCRAIG, MW
    HAWES, D
    WHITTINGTON, J
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (06) : 727 - 731
  • [8] LACK OF ALERTING REACTIONS TO INTERMITTENT CUFF INFLATIONS DURING NONINVASIVE BLOOD-PRESSURE MONITORING
    PARATI, G
    POMIDOSSI, G
    CASADEI, R
    MANCIA, G
    [J]. HYPERTENSION, 1985, 7 (04) : 597 - 601
  • [9] THE PROGNOSTIC VALUE OF AMBULATORY BLOOD PRESSURES
    PERLOFF, D
    SOKOLOW, M
    COWAN, R
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (20): : 2792 - 2798
  • [10] SCHWAN A, 1989, U STUDI MILANO RIC S, V76, P784