HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC ASSAY OF FOLIC-ACID - COLLABORATIVE STUDY

被引:6
作者
MCSHARRY, WO
MAHN, FP
机构
[1] Quality Control Department, Hoffmann-La Roche, Inc., Nutlev, New Jersey
基金
美国国家卫生研究院;
关键词
Folic acid—high‐pressure liquid chromatographic analysis in prepared samples; collaborative study; High‐pressure liquid chromatography—analysis; folic acid in prepared samples; collaborative study a Vitamins—folic acid; high‐pressure liquid chromatographic analysis in prepared samples;
D O I
10.1002/jps.2600680233
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A collaborative study of the USP high‐pressure liquid chromatographic assay for folic acid was performed. Two samples were analyzed in duplicate by 14 participating laboratories. Relative standard deviations for a single determination (RSDS) ranged from ±0.40 to ±2.39%. Based on an analysis of variance, it was concluded that the method of peak measurement was a major determinant of reproducibilily and that graphical measurement was associated with a high standard deviation. Adequate resolution was obtained using a variety of columns and operating conditions. The interlaboratory RSDS was ±1.8%. Copyright © 1979 Wiley‐Liss, Inc., A Wiley Company