SIMULTANEOUS ANALYSIS OF HYDROXYLAMINE, N-METHYLHYDROXYLAMINE AND N,N-DIMETHYLHYDROXYLAMINE BY ION CHROMATOGRAPHY

被引:29
作者
PROKAI, AM [1 ]
RAVICHANDRAN, RK [1 ]
机构
[1] BOEHRINGER MANNHEIM CORP,RES & DEV,INDIANAPOLIS,IN 46250
关键词
D O I
10.1016/0021-9673(94)89079-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydroxylamine and N-alkylhydroxylamines have been separated and analyzed using ion chromatography with conductivity and amperometric detectors. Conductivity detection is simple, but lacks selectivity. Amperometric detection provides good selectivity at modest working electrode operating potentials. However, in order to realize the selectivity, it is necessary to pretreat the working electrode which results in a significant reduction of the detector operating potential. While both conductivity and amperometric detectors have the capability to quantify nanomole amounts of hydroxylamines (absolute amount injected), amperometric detection possesses superior selectivity and sensitivity.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 9 条
[1]  
CHRISTIAN GD, 1980, ANAL CHEM, P186
[2]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[3]   THE APPLICATION OF A METALLIC COPPER ELECTRODE TO POTENTIOMETRIC DETECTION OF REDUCING SPECIES IN ION CHROMATOGRAPHY [J].
HADDAD, PR ;
ALEXANDER, PW ;
TROJANOWICZ, M .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (04) :777-789
[4]   ELECTROORGANIC PREPARATIONS .18. PREPARATION AND POLAROGRAPHIC DETERMINATION OF SOME N-ALKYLHYDROXYLAMINES [J].
IVERSEN, PE ;
LUND, H .
ACTA CHEMICA SCANDINAVICA, 1965, 19 (10) :2303-&
[5]   QUANTITATIVE-DETERMINATION OF HYDROXYLAMINE [J].
KOLASA, T ;
WARDENCKI, W .
TALANTA, 1974, 21 (08) :845-857
[6]   DETERMINATION OF HYDROXYLAMINE TRACES IN PROPIONOHYDROXAMIC ACID BULK DRUG AND PHARMACEUTICAL PREPARATIONS BY CAPILLARY GAS-CHROMATOGRAPHY [J].
LOMBARDI, F ;
CROLLA, T .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1988, 77 (08) :711-714
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF HYDROXYUREA IN PHARMACEUTICAL FORMULATIONS AND IN THE BULK [J].
PLUSCEC, J ;
YUAN, YC .
JOURNAL OF CHROMATOGRAPHY, 1986, 362 (02) :298-302
[8]   ENHANCEMENT OF LCEC RESPONSE BY USE OF ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
RAVICHANDRAN, K ;
BALDWIN, RP .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (10) :2031-2050
[9]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDRAZINES WITH ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ELECTRODES [J].
RAVICHANDRAN, K ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1782-1786