AN EVALUATION OF THE PENETRATION OF CERAMIC FEMORAL HEADS INTO POLYETHYLENE ACETABULAR CUPS

被引:30
作者
DOWSON, D
JOBBINS, B
SEYEDHARRAF, A
机构
[1] Department of Mechanical Engineering, The University of Leeds, Leeds
关键词
D O I
10.1016/0043-1648(93)90090-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
It is desirable to evaluate the performance of new designs of total replacement hip joints and new materials in joint simulators prior to clinical trials, yet few satisfactory hip joint simulators are available. In a previous paper (D. Dowson and B. Jobbins, Eng. Med., 17 (1988) 111-117) we have reported on the design and development of a versatile hip joint simulator and recorded an initial study of the performance of a standard 22 mm diameter Charnley prosthesis. There is now considerable interest in the use of ceramic femoral heads in total replacement hip joints and in the present paper we report the performance of larger diameter (32 mm) femoral heads made from high purity, fine grain alumina. A new procedure for the evaluation of penetration and wear volumes based upon the use of coordinate and roundness measuring machines is described. The results show a relatively rapid initial penetration of the femoral heads into the ultra-high molecular weight acetabular cups during the first 1.5 X 10(6) cycles of loading, followed by a very low penetration rate of about 27 mum per million cycles. This is shown to compare favourably with the previous findings for smaller, metallic Charnley prosthesis femoral heads of 22 mm diameter.
引用
收藏
页码:880 / 889
页数:10
相关论文
共 21 条
[1]   LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .3. THE MEASUREMENT OF INTERNAL VOLUME CHANGES IN EXPLANTED CHARNLEY SOCKETS AFTER 2-16 YEARS INVIVO AND THE DETERMINATION OF WEAR FACTORS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, JH ;
WROBLEWSKI, BM .
WEAR, 1985, 104 (03) :225-244
[2]   LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .2. A MICROSCOPICAL STUDY OF THE SURFACES OF CHARNLEY POLYETHYLENE ACETABULAR SOCKETS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, GH ;
WROBLEWSI, BM .
WEAR, 1985, 104 (03) :217-224
[3]  
Clarke I., 1989, PROGR BIOENGINEERING, P104
[4]  
COLLINS SN, 1990, THESIS U LEEDS
[5]   BIREFRINGENT STUDIES OF POLYETHYLENE WEAR SPECIMENS AND ACETABULAR CUPS [J].
COOPER, JR ;
DOWSON, D ;
FISHER, J .
WEAR, 1991, 151 (02) :391-402
[6]  
DOWNSON D, 1988, ENG MED, V17, P111
[7]   THE WEAR CHARACTERISTICS OF ULTRAHIGH MOLECULAR-WEIGHT POLYETHYLENE AGAINST A HIGH-DENSITY ALUMINA CERAMIC UNDER WET (DISTILLED WATER) AND DRY CONDITIONS [J].
DOWSON, D ;
HARDING, RT .
WEAR, 1982, 75 (02) :313-331
[8]  
DOWSON D, 1985, ACS SYM SER, V287, P215
[9]  
DOWSON D, 1985, ACS SYM SER, V287, P171
[10]   LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .1. CHARNLEY PROSTHESES WITH POLYTETRAFLUOROETHYLENE ACETABULAR CUPS [J].
DOWSON, D ;
WALLBRIDGE, NC .
WEAR, 1985, 104 (03) :203-215