SIMULTANEOUS REMOVAL OF NO AND SO2 IN PACKED SCRUBBERS OR SPRAY TOWERS

被引:37
作者
HARRIOTT, P
SMITH, K
BENSON, LB
机构
[1] Cornell University, Ithaca, New York
[2] Dravo Lime Company, Pittsburgh, Pennsylvania
[3] Radian Corp, Louisville, Kentucky
来源
ENVIRONMENTAL PROGRESS | 1993年 / 12卷 / 02期
关键词
D O I
10.1002/ep.670120207
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nitric oxide and sulfur dioxide can be removed from flue gas by scrubbing with a lime slurry containing ferrous EDTA. Tests in a 0.90m diameter column with several commercial packings gave 99 to 99.9 percent SO2 removal and 10 to 60 percent NO removal. The absorption of NO is controlled by the liquid-film resistance, and the number of transfer units varies with the square root of the ferrous EDTA concentration, the 0.4 to 0.6 power of the liquid rate, and the - 1.0 power of the gas velocity, in agreement with predictions. The height of a transfer unit for NO absorption, corrected for end effects, was 10 to 15m, about 30 times the estimated values for SO2 absorption, which is gas-film controlled. The spray tower gave lower removal rates for both gases, but the ratio of transfer units was about the same as for the packed columns.
引用
收藏
页码:110 / 113
页数:4
相关论文
共 8 条
[1]  
McCabe W.L., Smith J.C., Harriott P., Unit Operations of Chemical Engineering, (1985)
[2]  
Teramoto M., Hiramine S., Sugimoto, Teranishi H., J. Chem. Eng. Japan, 11, (1978)
[3]  
Narita E., Sato T., Shioya T., Ikari M., Okabe T., Ind. Eng. Chem. Prod. Res. Dev., 23, (1986)
[4]  
Chang S., Littlejohn D., Lynn S., Environ. Sci. Technol., 17, (1983)
[5]  
Huasheng L., Wenchi F., Ind. Eng. Chem. Res., 27, (1988)
[6]  
Tsai S.S., Bedell S.A., Kirby L.H., Zabick D.J., Environ. Progr., 8, (1989)
[7]  
Chemical Engineers' Handbook, pp. 3-98, (1985)
[8]  
(1992)