POWER BASED ALGORITHM TO PROVIDE LOSS OF GRID PROTECTION FOR EMBEDDED GENERATION

被引:7
作者
REDFERN, MA [1 ]
USTA, O [1 ]
FIELDING, G [1 ]
WALKER, EP [1 ]
机构
[1] GEC ALSTHOM PROTECT & CONTROL,ST LEONARDS WORKS,STAFFORD ST17 4LX,ENGLAND
关键词
POWER SYSTEM PROTECTION; EMBEDDED GENERATION; NONUTILITY GENERATION; LOSS OF GRID PROTECTION;
D O I
10.1049/ip-gtd:19941492
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper introduces a new protection algorithm designed to detect when the connection between an embedded generator operating and the utility grid is lost. Once loss of grid is detected, the intertie circuit breaker connecting the embedded generator to the utility should be opened to allow the orderly restoration of supply to other utility consumers. Failure to detect the loss of grid and subsequently open the intertie breaker could result in utility consumers receiving a low quality supply and could expose the embedded generator to severe damage should the utility grid be reconnected while out of synchronism with the embedded generator. The paper describes the basis for the operation of the protection algorithm and the role of the various elements together with the derivation of the tripping criterion. Its response to a series of power system switching scenarios are presented, including loss of grid, independent operation, out-of-phase reclosure, parallel operation together with a selection of fault studies, and for each it is shown to operate as required.
引用
收藏
页码:640 / 646
页数:7
相关论文
共 22 条
[1]  
Anderson P.M., 1977, POWER SYSTEM CONTROL
[2]  
CLARK HK, 1987, IEEE T IA, V25, P766
[3]  
COOPER CB, 1989, P INT C POW SYST PRO, P1
[5]   ELECTRIC DISTRIBUTION PROTECTION PROBLEMS ASSOCIATED WITH THE INTERCONNECTION OF SMALL, DISPERSED GENERATION DEVICES [J].
DUGAN, RC ;
RIZY, DT .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (06) :1121-1127
[6]  
FIELDING G, 1990, IEE REV, V4, P117
[7]   ANALYSIS OF UTILITY PROTECTION PROBLEMS ASSOCIATED WITH SMALL WIND TURBINE INTERCONNECTIONS [J].
PATTON, JB ;
CURTICE, D .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (10) :3957-3966
[8]   AN INDUSTRIAL VIEW OF UTILITY COGENERATION PROTECTION REQUIREMENTS [J].
POWELL, LJ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (01) :75-81
[9]   PROTECTION AGAINST LOSS OF UTILITY GRID SUPPLY FOR A DISPERSED STORAGE AND GENERATION UNIT [J].
REDFERN, MA ;
USTA, O ;
FIELDING, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) :948-954
[10]   APPLICATION OF PROTECTIVE RELAYS ON A LARGE INDUSTRIAL-UTILITY TIE WITH INDUSTRIAL CO-GENERATION [J].
ROOK, MJ ;
GOFF, LE ;
POTOCHNEY, GJ ;
POWELL, LJ .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (06) :2804-2812