RF COIL OPTIMIZATION - EVALUATION OF B-1 FIELD HOMOGENEITY USING FIELD HISTOGRAMS AND FINITE-ELEMENT CALCULATIONS

被引:37
作者
LI, SZ [1 ]
YANG, QX [1 ]
SMITH, MB [1 ]
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,COLL MED,CTR NMR RES,DEPT RADIOL,HERSHEY,PA 17033
关键词
RADIOFREQUENCY COIL; FINITE ELEMENT ANALYSIS; FIELD HISTOGRAM; EDDY CURRENT; MRI;
D O I
10.1016/0730-725X(94)91240-W
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional (2D) finite element analysis has been used to solve the full set of Maxwell's equations for the 2D magnetic field of radiofrequency (RF) coils. The field histogram method has been applied to evaluate and optimize the magnetic field homogeneity of some commonly used RF coils: the saddle coil, the slotted tube resonator, the multiple elements coil and the birdcage resonator, as well as the radial plate coil. Each coil model represents a cross-section of an infinitely long cylinder. The optimum configuration of each of these five RF coils is suggested. It was found that field homogeneity is more strongly dependent on the coil's window angle than on any other parameter. Additionally, eddy currents in the coil's conductive elements distort the current and magnetic field distribution. The frequency dependence of this eddy current distortion is analyzed and discussed.
引用
收藏
页码:1079 / 1087
页数:9
相关论文
共 24 条
  • [1] Hoult, Richards, The signal-to-noise ratio of the nuclear magnetic resonance experiment, J. Magn. Reson., 24, pp. 71-83, (1976)
  • [2] Bolinger, Prammer, Leigh, A multiple-frequency coil with a highly uniform B<sub>1</sub> field, J. Magn. Reson., 81, pp. 162-166, (1988)
  • [3] Hoult, Rotating frame zeugmatography, J. Magn. Reson., 33, pp. 183-197, (1990)
  • [4] Murphy-Boesch, So, James, Precision mapping of the B<sub>1</sub> field using the rotating frame experiment, J. Magn. Reson., 73, pp. 293-303, (1987)
  • [5] Hornak, Szumowski, Bryant, Magnetic field mapping, Magn. Reson. Med., 6, pp. 158-163, (1988)
  • [6] Lian, Zha, Lowe, An NMR technique for measuring the RF magnetic field distribution of NMR coils, Book of abstracts: Tenth Annual Meeting of the Society of Magnetic Resonance in Medicine, (1991)
  • [7] Oh, Hilal, Cho, Mun, Radiofrequency field intensity mapping using a composite spin-echo sequence, Magn. Reson. Imaging, 8, pp. 21-25, (1990)
  • [8] Talagala, Gillen, Experimental determination of three-dimensional RF magnetic field distribution of NMR coils, J. Magn. Reson., 94, pp. 493-500, (1991)
  • [9] Mehr, Koeller, Kuhn, Quality assessment of RF coils by B<sub>1</sub>-field-spectroscopy, Book of abstracts: 33rd Experimental Nuclear Magnetic Resonance Conference, (1992)
  • [10] Hanssum, Maurer, Ruterjans, Elimination of systematic errors in fast inversion-recovery spin-lattice relaxation time measurements, J. Magn. Reson., 31, pp. 231-249, (1978)