HIGH PH MOBILE-PHASE EFFECTS ON SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS

被引:166
作者
KIRKLAND, JJ [1 ]
VANSTRATEN, MA [1 ]
CLAESSENS, HA [1 ]
机构
[1] EINDHOVEN UNIV TECHNOL,DEPT CHEM,5600 MB EINDHOVEN,NETHERLANDS
关键词
D O I
10.1016/0021-9673(94)00631-I
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aqueous mobile phases above pH 8 often cause premature column failure, limiting the utility of silica-based columns for applications requiring high PH. Previous studies suggest that covalently bound silane ligands are hydrolyzed and removed by high-pH mobile phases. However, we found that the siloxane bonds for certain monomeric silanes are hydrolyzed very slowly from silica supports at pH 9-10. Therefore, bonded-phase packing degradation at high pH is a result mainly of silica support dissolution. The rate of column degradation for C-18 columns is influenced not only by the type and purity of silica support, but also by the nature of the silane stationary phase. We found different rates of degradation for several commercial C-18 columns. The relative rates of silica dissolution for these packings were determined by chemically measuring the silicate formed during column purging at high pH. The type and concentration of mobile phase organic modifier also significantly influences column degradation at high pH. Certain silica-based C-18 packings can be used for long periods at pH 9 without significant changes in chromatographic properties. Results of this study better define the practical utility and limitations of silica-based columns in high pH environments.
引用
收藏
页码:3 / 19
页数:17
相关论文
共 27 条
[1]   IMPROVEMENTS IN LIQUID-CHROMATOGRAPHY COLUMN LIFE AND METHOD FLEXIBILITY BY SATURATING THE MOBILE PHASE WITH SILICA [J].
ATWOOD, JG ;
SCHMIDT, GJ ;
SLAVIN, W .
JOURNAL OF CHROMATOGRAPHY, 1979, 171 (APR) :109-115
[2]   DISSOLUTION OF SILACEOUS CHROMATOGRAPHIC PACKINGS IN VARIOUS AQUEOUS ELUENTS [J].
BARKER, PE ;
HATT, BW ;
HOLDING, SR .
JOURNAL OF CHROMATOGRAPHY, 1981, 206 (01) :27-34
[3]   SILICA - BACKBONE MATERIAL OF LIQUID-CHROMATOGRAPHIC COLUMN PACKINGS [J].
BERTHOD, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :1-28
[4]  
BOYES BE, 1993, PEPT RES, V5, P249
[5]   THE INFLUENCE OF SILICA STRUCTURE ON REVERSED-PHASE RETENTION [J].
COX, GB .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :353-367
[6]  
DESTEFANO JJ, 1992, COMMUNICATION JUL
[7]   STUDY OF THE CHANGES IN MONOFUNCTIONAL, DIFUNCTIONAL AND TRIFUNCTIONAL OCTADECYL-MODIFIED PACKINGS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIFFERENT ELUENT COMPOSITIONS [J].
HETEM, M ;
VANDEVEN, L ;
DEHAAN, J ;
CRAMERS, C .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (02) :269-295
[8]   LIQUID-CHROMATOGRAPHY OF IONOGENIC SUBSTANCES WITH NONPOLAR STATIONARY PHASES [J].
HORVATH, C ;
MELANDER, W ;
MOLNAR, I .
ANALYTICAL CHEMISTRY, 1977, 49 (01) :142-154
[9]  
Iler K.R., 1979, CHEM SILICA SOLUBILI
[10]  