INFLUENCE OF BALLOON SIZE AND STENOSIS MORPHOLOGY ON IMMEDIATE AND DELAYED ELASTIC RECOIL AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY

被引:58
作者
HANET, C [1 ]
WIJNS, W [1 ]
MICHEL, X [1 ]
SCHROEDER, E [1 ]
机构
[1] CATHOLIC UNIV LOUVAIN,SCH MED,DIV CARDIOL,B-1200 BRUSSELS,BELGIUM
关键词
D O I
10.1016/0735-1097(91)90607-B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
After successful coronary angioplasty, the minimal luminal diameter of the dilated coronary artery segment is generally smaller than the diameter of the largest balloon catheter at the maximal inflation pressure. The determinants of this phenomenon were studied in 28 patients. Biplane angiograms were obtained after intracoronary administration of isosorbide dinitrate (1 mg) before, immediately and 24 h after coronary angioplasty. Balloon and coronary luminal diameters were measured by automated contour detection. Immediately after the procedure, the difference between inflated balloon diameter and minimal luminal diameter averaged 0.93 +/- 0.43 mm for the entire group and was greater both in eccentric stenoses (1.13 +/- 0.39 vs. 0.70 +/- 0.36 mm; p < 0.0 1) and after angioplasty with an oversized balloon (1.20 +/- 0.37 vs. 0.71 +/- 0.33 mm; p < 0.005). At 24 h, the balloon-minimal luminal diameter difference was unchanged at the group level (0.86 +/- 0.38 mm), but the minimal luminal diameter increased significantly in the subgroup of coronary segments dilated with an oversized balloon (1.97 +/- 0.37 vs. 1.81 +/- 0.28 mm; p < 0.05). Thus, the difference between the minimal diameter of a dilated coronary segment immediately after a successful coronary balloon angioplasty procedure and the maximal diameter of the inflated balloon catheter is dependent both on eccentricity of the stenosis and on the balloon/artery diameter ratio. Moreover, the increase in minimal luminal diameter 24 h after angioplasty performed with an oversized balloon suggests that in addition to elastic recoil. partly reversible factors related to vessel barotrauma are involved.
引用
收藏
页码:506 / 511
页数:6
相关论文
共 16 条
  • [1] TRANS-LUMINAL ANGIOPLASTY - CORRELATION OF MORPHOLOGIC AND ANGIOGRAPHIC FINDINGS IN AN EXPERIMENTAL-MODEL
    BLOCK, PC
    BAUGHMAN, KL
    PASTERNAK, RC
    FALLON, JT
    [J]. CIRCULATION, 1980, 61 (04) : 778 - 785
  • [2] RELEASE OF ATHEROSCLEROTIC DEBRIS AFTER TRANS-LUMINAL ANGIOPLASTY
    BLOCK, PC
    ELMER, D
    FALLON, JT
    [J]. CIRCULATION, 1982, 65 (05) : 950 - 952
  • [3] BONZEL TR, 1989, INTERVENTIONAL CARDI, P320
  • [4] BOURASSA M G, 1988, European Heart Journal, V9, P1034
  • [5] IMPORTANCE OF STENOSIS MORPHOLOGY IN THE ESTIMATION OF RESTENOSIS RISK AFTER ELECTIVE PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    ELLIS, SG
    ROUBIN, GS
    KING, SB
    DOUGLAS, JS
    COX, WR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (01) : 30 - 34
  • [6] MYOCARDIAL PROTECTION BY INTRACORONARY NICARDIPINE ADMINISTRATION DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    HANET, C
    ROUSSEAU, MF
    VINCENT, MF
    LAVENNEPARDONGE, E
    POULEUR, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (12) : 1035 - 1040
  • [7] DOES LENGTH OR ECCENTRICITY OF CORONARY STENOSES INFLUENCE THE OUTCOME OF TRANS-LUMINAL DILATATION
    MEIER, B
    GRUENTZIG, AR
    HOLLMAN, J
    ISCHINGER, T
    BRADFORD, JM
    [J]. CIRCULATION, 1983, 67 (03) : 497 - 499
  • [8] ASSESSMENT OF SHORT-TERM, MEDIUM-TERM, AND LONG-TERM VARIATIONS IN ARTERIAL DIMENSIONS FROM COMPUTER-ASSISTED QUANTITATION OF CORONARY CINEANGIOGRAMS
    REIBER, JHC
    SERRUYS, PW
    KOOIJMAN, CJ
    WIJNS, W
    SLAGER, CJ
    GERBRANDS, JJ
    SCHUURBIERS, JCH
    DENBOER, A
    HUGENHOLTZ, PG
    [J]. CIRCULATION, 1985, 71 (02) : 280 - 288
  • [9] REIBER JHC, 1986, STATE ART QUANTITATI, P145
  • [10] REVERSAL OF SEGMENTAL HYPOKINESIS BY CORONARY ANGIOPLASTY IN PATIENTS WITH UNSTABLE ANGINA, PERSISTENT T-WAVE INVERSION, AND LEFT ANTERIOR DESCENDING CORONARY-ARTERY STENOSIS - ADDITIONAL EVIDENCE FOR MYOCARDIAL STUNNING IN HUMANS
    RENKIN, J
    WIJNS, W
    LADHA, Z
    COL, J
    [J]. CIRCULATION, 1990, 82 (03) : 913 - 921