EXPOSURE TO CHLORAMINES IN THE ATMOSPHERE OF INDOOR SWIMMING POOLS

被引:111
作者
HERY, M
HECHT, G
GERBER, JM
GENDRE, JC
HUBERT, G
REBUFFAUD, J
机构
[1] LAB INTERREG CHIM OUEST,NANTES,FRANCE
[2] CRAM NORMANDIE,CHIM LAB,ROUEN,FRANCE
关键词
D O I
10.1016/0003-4878(95)00013-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Specific sampling and analytical methods were developed to assess the concentration of chloramines in the atmosphere of indoor swimming pools because swimming instructors had complained of irritation (mainly eye and lung). The sampling method is based upon the reduction of chloramines to chlorides which are then analysed by ion chromatography. The chloramine concentration in the atmosphere of 13 swimming pools (including five recreational centres and one re-education centre) was measured, showing that the concentrations were higher in the recreational centres. The influence of slides, bubbling baths, waves and other activities were demonstrated. A correlation was made between the level of pollutants and the complaints registered, leading to the proposal of a 'comfort' limit value.
引用
收藏
页码:427 / 439
页数:13
相关论文
共 13 条
[1]   PLASMA CHLOROFORM CONCENTRATIONS IN SWIMMERS USING INDOOR SWIMMING POOLS [J].
AGGAZZOTTI, G ;
FANTUZZI, G ;
TARTONI, PL ;
PREDIERI, G .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1990, 45 (03) :175-179
[2]   CHLOROFORM IN ALVEOLAR AIR OF INDIVIDUALS ATTENDING INDOOR SWIMMING POOLS [J].
AGGAZZOTTI, G ;
FANTUZZI, G ;
RICHI, E ;
TARTONI, P ;
CASSINADRI, T ;
PREDIERI, G .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1993, 48 (04) :250-254
[3]   BIOASSAY FOR EVALUATING THE POTENCY OF AIRBORNE SENSORY IRRITANTS AND PREDICTING ACCEPTABLE LEVELS OF EXPOSURE IN MAN [J].
ALARIE, Y .
FOOD AND COSMETICS TOXICOLOGY, 1981, 19 (05) :623-626
[4]   ACUTE INHALATION TOXICOLOGY OF NITROGEN TRICHLORIDE [J].
BARBEE, SJ ;
THACKARA, JW ;
RINEHART, WE .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1983, 44 (02) :145-146
[5]  
BRUNETTO M, 1987, ANALUSIS, V15, P393
[6]   COMPARISON OF THE SENSORY IRRITATION RESPONSE IN MICE TO CHLORINE AND NITROGEN TRICHLORIDE [J].
GAGNAIRE, F ;
AZIM, S ;
BONNET, P ;
HECHT, G ;
HERY, M .
JOURNAL OF APPLIED TOXICOLOGY, 1994, 14 (06) :405-409
[7]  
Hailin G. E., 1990, ANAL CHIM ACTA, V237, P149
[8]   THE FATE OF CHLORINE AND CHLORAMINES IN COOLING-TOWERS - HENRYS LAW CONSTANTS FOR FLASHOFF [J].
HOLZWARTH, G ;
BALMER, RG ;
SONI, L .
WATER RESEARCH, 1984, 18 (11) :1421-1427
[9]  
JESSEN H-J, 1986, Zeitschrift fuer die Gesamte Hygiene und ihre Grenzgebiete, V32, P180
[10]  
LAHL U, 1981, WATER RES, V15, P503