DEVELOPMENT AND APPLICATION OF A RADIOIMMUNOASSAY FOR FLUPHENAZINE BASED ON MONOCLONAL-ANTIBODIES AND ITS COMPARISON WITH ALTERNATE ASSAY-METHODS

被引:13
作者
MCKAY, G
STEEVES, T
COOPER, JK
HAWES, EM
MIDHA, KK
机构
[1] College of Pharmacy, University of Saskatchewan, Saskatoon, Saskatchewan
关键词
D O I
10.1002/jps.2600790313
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The development of a monoclonal antibody towards fluphanazine allows the measurement of plasma concentrations of this highly potent neuroleptic. The method demonstrates sufficient sensitivity to measure 0.02 ng of fluphenazine per milliliter of plasma and employs a 150‐μL plasma extract derived from a 2‐mL plasma sample. The procedure is linear over the concentration range of 0.02 to 2.5 ng/mL, with a mean overall coefficient of variation of <3%. The validity of the described monoclonal‐based RIA procedure was confirmed by comparison to alternate assay methods in replicate samples. Comparison to a newly developed HPLC‐coulometric procedure in 159 samples showed a strong correlation, with a slope value of close to unity (1.0484) and a coefficient of correlation of 0.8136, while comparison to a previously developed polyclonal‐based RIA procedure showed a correlation of 0.95 and a slope of 0.91 (n = 26). Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:240 / 243
页数:4
相关论文
共 14 条
[1]   SOLID-PHASE RADIOIMMUNOASSAY OF ESTRADIOL-17BETA [J].
ABRAHAM, GE .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1969, 29 (06) :866-+
[2]   PREPARATION AND CHARACTERIZATION OF ANTISERA AND MONOCLONAL-ANTIBODIES TO HALOPERIDOL [J].
BOLGER, MB ;
FLURKEY, K ;
SIMMONS, RD ;
LINTHICUM, DS ;
LADURON, P ;
MICHIELS, M .
IMMUNOLOGICAL INVESTIGATIONS, 1985, 14 (06) :523-540
[3]   AN ULTRASENSITIVE METHOD FOR THE MEASUREMENT OF FLUPHENAZINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COULOMETRIC DETECTION [J].
COOPER, JK ;
HAWES, EM ;
HUBBARD, JW ;
MCKAY, G ;
MIDHA, KK .
THERAPEUTIC DRUG MONITORING, 1989, 11 (03) :354-360
[4]  
ERLANGER BF, 1959, J BIOL CHEM, V234, P1090
[5]  
GALFRE G, 1981, METHOD ENZYMOL, V73, P4
[6]   PICOGRAM LEVEL DETERMINATION OF FLUPHENAZINE IN HUMAN-PLASMA BY AUTOMATED GAS-CHROMATOGRAPHY MASS SELECTIVE DETECTION [J].
JEMAL, M ;
IVASHKIV, E ;
BOTH, D ;
KOSKI, R ;
COHEN, AI .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (12) :699-704
[7]   MONOCLONAL-ANTIBODIES TO THE CHEMOTHERAPEUTIC AGENT METHOTREXATE - PRODUCTION, PROPERTIES AND COMPARISON WITH POLYCLONAL ANTIBODIES [J].
KATO, Y ;
PATERSON, A ;
LANGONE, JJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 67 (02) :321-336
[8]   A HIGHLY SENSITIVE AND SPECIFIC RADIOIMMUNOASSAY FOR QUANTITATION OF PLASMA FLUPHENAZINE [J].
LO, ES ;
FEIN, M ;
HUNTER, C ;
SUCKOW, RF ;
COOPER, TB .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1988, 77 (03) :255-258
[9]   SUBNANOGRAM DETERMINATION OF FLUPHENAZINE IN HUMAN-PLASMA BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MCKAY, G ;
HALL, K ;
EDOM, R ;
HAWES, EM ;
MIDHA, KK .
BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (10) :550-555
[10]  
MIDHA KK, 1984, BIOPHARM DRUG DISPOS, V5, P25, DOI 10.1002/bdd.2510050105