NONINVASIVE EVALUATION OF THE CONDUIT FUNCTION AND THE BUFFERING FUNCTION OF LARGE ARTERIES IN MAN

被引:30
作者
DEMOLIS, PD
ASMAR, RG
LEVY, BI
SAFAR, ME
机构
[1] HOP BROUSSAIS,INSERM,U337,F-75674 PARIS 14,FRANCE
[2] HOP LARIBOISIERE,INSERM,U141,F-75475 PARIS 10,FRANCE
来源
CLINICAL PHYSIOLOGY | 1991年 / 11卷 / 06期
关键词
ARTERIAL COMPLIANCE; BLOOD FLOW; PERIPHERAL LARGE ARTERIES;
D O I
10.1111/j.1475-097X.1991.tb00675.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to validate a two-dimensional (2D) echography coupled range-gated Doppler system for the non-invasive measurement of internal diameter, blood flow velocity, and pulse wave velocity of peripheral arteries, such as the common carotid artery (CCA), femoral artery (FA), and brachial artery (BA) in man. The array of the ultrasonic system and the Doppler probe were attached and formed a fixed angle (38-degrees 30'). The artery was firstly visualized using the echographic array probe in order to position the Doppler beam. Then, the range-gated Doppler system was used to measure both internal diameter and blood flow velocity with the sample volume position covering the internal diameter. Using a hydraulic device, there was an obvious correlation between the calculated and the measured velocities (r = 0.98). Normal values of diameter, blood flow velocity and blood flow were measured in 18 healthy volunteers. The means (+/- 1 standard deviation) was as follows: diameter, CCA = 0.636 +/- 0.027 cm, FA = 0.843 +/- 0.074 cm, BA = 0.302 +/-0.052 cm; flow velocity, CCA = 19.5 +/- 2.1 cm s-1, FA = 11.4 +/- 1.2 cm s-1, BA = 6.7 +/- 1.0 cm s-1. Blood flows were as follows: CCA, 370.6 +/- 42.5 ml mn-1, FA 387.0 +/- 75.0 ml mn-1 and BA (wrist occlusion) 29.8 +/- 12.5 ml mn-1. The intra-observer reproducibilities for CCA, FA and BA were respectively: for diameter, 4.9%, 4.12% and 14.8%; for velocity, 8.9%, 10.6% and 10.2%. The inter-observer reproducibilities were respectively: for diameter, 5.6%, 5.4% and 11.3% for velocity, 6.5%, 5.7% and 6.3%. Simultaneous determinations of pulse wave velocity from blood flow velocity recording allowed estimations of the distensibility of these arteries. Finally, the coupled echo and range-gated Doppler system permitted non-invasive evaluation of blood flow calculated as the product of the vessel cross-sectional area and measured blood velocity and also of arterial compliance as the ratio of the cross-sectional area and the square of pulse wave velocity. Such estimations of the conduit and buffering functions of peripheral large arteries in man were shown to be more accurate for the common carotid and the femoral arteries than for the brachial artery.
引用
收藏
页码:553 / 564
页数:12
相关论文
共 22 条
  • [1] REVERSION OF CARDIAC-HYPERTROPHY AND REDUCED ARTERIAL COMPLIANCE AFTER CONVERTING ENZYME-INHIBITION IN ESSENTIAL-HYPERTENSION
    ASMAR, RG
    PANNIER, B
    SANTONI, JP
    LAURENT, S
    LONDON, GM
    LEVY, BI
    SAFAR, ME
    [J]. CIRCULATION, 1988, 78 (04) : 941 - 950
  • [2] AVOLIO AP, 1987, ARTERIAL VENOUS SYST, P133
  • [4] EFFECTS OF ISOSORBIDE DINITRATE ON THE PATTERN OF ARTERIAL BLOOD-FLOW IN HEALTHY-HUMAN SUBJECTS
    CARO, CG
    FISH, PJ
    GOSS, DE
    HALLS, J
    LEVER, MJ
    PARKER, KH
    CLEAR, AS
    [J]. CLINICAL SCIENCE, 1990, 79 (03) : 215 - 220
  • [5] GISVOLD SE, 1982, CARDIOVASC RES, V16, P26, DOI 10.1093/cvr/16.1.26
  • [6] EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS
    GOLDBERG, SJ
    SAHN, DJ
    ALLEN, HD
    VALDESCRUZ, LM
    HOENECKE, H
    CARNAHAN, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) : 1394 - 1400
  • [7] PULSATILE DIAMETER AND ELASTIC-MODULUS OF THE AORTIC-ARCH IN ESSENTIAL-HYPERTENSION - A NONINVASIVE STUDY
    ISNARD, RN
    PANNIER, BM
    LAURENT, S
    LONDON, GM
    DIEBOLD, B
    SAFAR, ME
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (02) : 399 - 405
  • [8] FLOW-DEPENDENT VASODILATION OF BRACHIAL-ARTERY IN ESSENTIAL-HYPERTENSION
    LAURENT, S
    LACOLLEY, P
    BRUNEL, P
    LALOUX, B
    PANNIER, B
    SAFAR, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04): : H1004 - H1011
  • [9] HAND ARTERIAL BLOOD-FLOW RESPONSES TO LOCAL VENOUS CONGESTION
    LEVY, BI
    OLIVA, Y
    MARTINEAUD, JP
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (06): : H980 - H983
  • [10] COMPARISON OF PLETHYSMOGRAPHIC METHODS WITH PULSED DOPPLER BLOOD FLOWMETRY
    LEVY, BI
    VALLADARES, WR
    GHAEM, A
    MARTINEAUD, JP
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (06): : H899 - H903