SIMPLE METHOD FOR THE PREPARATION OF WATER-MODIFIED OR METHANOL-MODIFIED CARBON-DIOXIDE AS THE MOBILE-PHASE IN SUPERCRITICAL-FLUID CHROMATOGRAPHY

被引:9
作者
PYO, DJ
JU, DW
机构
[1] Department of Chemistry, Kangweon National University
关键词
SUPERCRITICAL FLUID CHROMATOGRAPHY; SUPERCRITICAL CARBON DIOXIDE; MODIFIED CARBON DIOXIDE;
D O I
10.2116/analsci.10.171
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The polarity range of solutes that can be separated by supercritical fluid chromatography (SFC) can be greatly extended by the addition of polar modifiers to supercritical CO2. In this paper, a new mixing device was introduced, in which highly porous stainless-steel filters were used to generate water-modified or methanol-modified carbon dioxide mobile phases. When supercritical CO2 goes through the mixing device, modifiers held within the small pores of filters can be dissolved in the pressurized supercritical fluids. Among the many stainless-steel filters with different porosities which were tested, 0.5 and 2 mum stainless-steel filters were more effective than the others. To measure the amount of modifiers dissolved in supercritical CO2 after the mixing device, a modifier sensor which consists of a polymer film, i.e. a film of a perfluorosulfonate ionomer (PFSI), was used.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 12 条
[1]   MODIFIER EFFECTS ON RETENTION AND PEAK SHAPE IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BLILIE, AL ;
GREIBROKK, T .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2239-2242
[2]   SUPERCRITICAL FLUID CHROMATOGRAPHY OF POLAR DRUGS USING SMALL-PARTICLE PACKED-COLUMNS WITH MASS-SPECTROMETRIC DETECTION [J].
CROWTHER, JB ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2711-2716
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS AND STATIONARY PHASES IN SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
ENGELHARDT, H ;
GROSS, A ;
MERTENS, R ;
PETERSEN, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 477 (01) :169-183
[4]   NEW SYSTEM FOR DELIVERY OF THE MOBILE PHASE IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
GREIBROKK, T ;
BLILIE, AL ;
JOHANSEN, EJ ;
LUNDANES, E .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2681-2684
[5]   AMPEROMETRIC MICROSENSOR FOR WATER [J].
HUANG, HL ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1935-1942
[6]  
KLESPER E, 1962, J ORG CHEM, V27, P700
[7]   INVESTIGATIONS OF THE USES OF MODIFIERS IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
LEVY, JM ;
RITCHEY, WM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (06) :242-248
[8]   MONITORING THE MOBILE-PHASE COMPOSITION IN SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
PYO, DJ ;
HWANG, H .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :103-109
[9]   ADDITION AND MEASUREMENT OF WATER IN CARBON-DIOXIDE MOBILE PHASE FOR SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
PYO, DN ;
JU, D .
ANALYST, 1993, 118 (03) :253-255
[10]   COMPARISON OF PACKED AND CAPILLARY COLUMNS FOR PRACTICAL SFC SEPARATIONS [J].
SCHWARTZ, HE ;
BARTHEL, PJ ;
MORING, SE ;
YATES, TL ;
LAUER, HH .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (03) :204-206