SCANNING ELECTRON-MICROSCOPIC INVESTIGATIONS OF SURFACE-TREATED LARGE-BORE CATHETERS USED FOR EXTRACORPOREAL DETOXIFICATION METHODS

被引:14
作者
BAMBAUER, R [1 ]
SCHIEL, R [1 ]
MESTRES, P [1 ]
SIOSHANSI, P [1 ]
机构
[1] SPIRE CORP,BEDFORD,MA
关键词
LARGE-BORE CATHETERS; ION BEAM-BASED TECHNOLOGIES; CATHETER COMPLICATIONS;
D O I
10.1177/039139889501800606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Typical complications caused by surface properties of synthetic catheter implants are infection, thrombosis, and stenosis. New methods for surface modification with the aim of reducing such complications are ion beam-based technologies. In our study 109 large-bore catheters without (n = 42) and with treated surfaces with silver (n = 39) or silicone (n = 28) were inserted into the interna jugular and the subclavian veins and were used for extracorporeal detoxification methods. After removal, the catheters were investigated with scanning electron microscopy (SEM) and for bacterial colonization. In 42 large-bore catheters without surface treatment deposits of fibrin, protein and blood cells were seen on the inner and outer surface. Bacterial colonization was observed In 38.1%. In contrast, the catheters with treated outer surfaces showed a very low thrombogenecity and a low contamination rate of 8.9%. The ion beam-based technologies reduce the thrombogenicity and infection rates of the catheter surfaces. In comparison to catheters without treated surfaces, catheters with surface treatment are good alternatives in blood contacting applications ranging from hemodialysis to oncology.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 20 条
  • [1] Bambauer R, 1992, ASAIO J, V38, P96, DOI 10.1097/00002480-199204000-00006
  • [2] BAMBAUER R, 1994, SCANNING ELECTRON MI, V18, P272
  • [3] BAMBAUER R, 1991, VASCULAR ACCESS BLOO, P107
  • [4] BAUMBAUER R, 1982, DIALYSIS TRANSPLANT, V11, P766
  • [5] BAUMBAUER R, 1994, ARTIF ORGANS, V18, P318
  • [6] BAUMBAUER R, 1992, ASAIO, V38, P96
  • [7] DIAGNOSIS AND MANAGEMENT OF SUBCLAVIAN VEIN-THROMBOSIS OCCURRING IN ASSOCIATION WITH SUBCLAVIAN CANNULATION FOR HEMODIALYSIS
    BRADY, HR
    FITZCHARLES, B
    GOLDBERG, H
    HURAIB, S
    RICHARDSON, T
    SIMONS, M
    ULDALL, PR
    [J]. BLOOD PURIFICATION, 1989, 7 (04) : 210 - 217
  • [8] DENSITY ENHANCEMENT IN ION-IMPLANTED POLYMERS
    CALCAGNO, L
    FOTI, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 19-20 : 895 - 898
  • [9] ION IRRADIATION OF POLYMERS
    CALCAGNO, L
    FOTI, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 59 : 1153 - 1158
  • [10] Kjellstrand C M, 1975, Clin Nephrol, V4, P37