BLOOD-PRESSURE MEASUREMENT ERROR - ITS EFFECT ON CROSS-SECTIONAL AND TREND ANALYSES

被引:39
作者
BENNETT, S
机构
[1] National Centre for Epidemiology and Population Health, Australian National University, Canberra
关键词
BLOOD PRESSURE; DATA QUALITY; OBSERVER BIAS; TRENDS; MEASUREMENT ERROR;
D O I
10.1016/0895-4356(94)90010-8
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The measurement of blood pressure in epidemiological studies is difficult to standardize between centres in multi-centre studies and between repeat surveys over time. The use of standard mercury sphygmomanometers in common but especially prone to measurement error in terms of departure from the protocol and variation in measurement technique. Data from Australias cardiovascular risk factor prevalence surveys on 21 independent populations, distributed geographically and temporally, has been examined to assess the effect of these errors on cross-sectional and trend analyses. The examination showed that last digit preference for zero may inflate estimates of proportions having high blood pressure. A tendency to record identical duplicate measurements could contribute 0.85 mmHg to time trends or geographic differences in mean systolic blood pressure (but not diastolic blood pressure). Epidemiological studies for geographic and trend differentials in systolic blood pressure need to mindful of these effects in their analysis. There was some evidence of deterioration in data quality during data collection but no evidence that observers were influenced in their recording practice by observable respondents. characteristics. Training procedures for blood pressure measurement are of critical importance and adherence to the measurement protocol should by continuously monitored during data collection to ensure comparability of results
引用
收藏
页码:293 / 301
页数:9
相关论文
共 21 条
[1]  
BEAGLEHOLE R, 1990, EPIDEMIOL REV, V12, P1
[2]   THE HYPERTENSION PREVENTION TRIAL - ASSESSMENT OF THE QUALITY OF BLOOD-PRESSURE MEASUREMENTS [J].
CANNER, PL ;
BORHANI, NO ;
OBERMAN, A ;
CUTLER, J ;
PRINEAS, RJ ;
LANGFORD, H ;
HOOPER, FJ .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (04) :379-392
[3]  
Choi S C, 1978, J Nurs Educ, V17, P38
[4]   THE RANDOM-ZERO VERSUS THE STANDARD MERCURY SPHYGMOMANOMETER - A SYSTEMATIC BLOOD-PRESSURE DIFFERENCE [J].
DEGAUDEMARIS, R ;
FOLSOM, AR ;
PRINEAS, RJ ;
LUEPKER, RV .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1985, 121 (02) :282-290
[5]  
DISCHINGER P, 1986, CONTROL CLIN TRIALS, V7, pS137
[6]  
DRIZD T, 1986, VITAL HLTH STATISTIC, V11
[7]  
EILERTSE.E, 1968, ACTA MED SCAND, V184, P145
[8]   BLOOD-PRESSURE MEASUREMENT IN THE UNITED-KINGDOM HEART-DISEASE PREVENTION PROJECT [J].
HELLER, RF ;
ROSE, G ;
PEDOE, HDT ;
CHRISTIE, DGS .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1978, 32 (04) :235-238
[9]  