COMPARISON OF PRESSURE AND FLOW TRIGGERING SYSTEMS DURING CONTINUOUS POSITIVE AIRWAY PRESSURE

被引:26
作者
BRANSON, RD [1 ]
CAMPBELL, RS [1 ]
DAVIS, K [1 ]
JOHNSON, DJ [1 ]
机构
[1] TAMPA GEN HOSP,DEPT SURG,TAMPA,FL 33606
关键词
D O I
10.1378/chest.106.2.540
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: Compare the inspiratory work of breathing (WOBI) during pressure triggering (PT), and now triggering (FT) using two microprocessor ventilators. Design: A randomized, crossover comparison of triggering strategies and ventilators was used. Setting: Surgical intensive care unit. Patients: Ten patients recovering from acute respiratory failure (eight men, two women; mean age, 48 +/- 12 years) breathing on continuous positive airway pressure (CPAP) of 5 cm H2O were studied. Interventions: Patients were randomly assigned to either receive 5 cm H2O CPAP via one of two units (Hamilton Veolar or Puritan Bennett 7200ae) using either PT or FT. Each patient had 30-min trials using the following: (1) Veolar PT; (2) Veolar PT; (3) 7200ae ET; and (4) 7200ae ET. Measurements and results: During each trial period, work of breathing (WOB) and pressure time product (PTP) were measured using a respiratory monitor (Bicore CP-100). All patients were placed in semi-Fowler position and esophageal balloons were inserted and their position confirmed using the occlusion technique. Continuous measurements of peak negative pressure during inspiration, tidal volume (VT), minute ventilation (VE), respiratory frequency (f) were accomplished with a how transducer at the proximal airway. FT with the 7200ae was superior to PT as measured by both the WOB (0.58 +/- 0.3 vs 0.84 +/- 0.2 J/L, p<0.01) and PTP (148 +/- 50 vs 206 +/- 41 cm H2O/s/min, p<0.05). FT with the Veolar was also superior to PT with respect to the WOB (0.53 +/- 0.2 vs 0.93 +/- 0.2 J/L, p<0.01) and PTP (140 +/- 39 vs 229 +/- cm H2O/s/min, p<0.05). Conclusion: FT reduces the WOB compared with PT, regardless of the ventilator used. The reduction in WOB during FT is related to improved responsiveness and changes in the posttrigger phase.
引用
收藏
页码:540 / 544
页数:5
相关论文
共 23 条
[1]   SITE OF PRESSURE MEASUREMENT DURING SPONTANEOUS BREATHING WITH CONTINUOUS POSITIVE AIRWAY PRESSURE - EFFECT ON CALCULATING IMPOSED WORK OF BREATHING [J].
BANNER, MJ ;
KIRBY, RR ;
BLANCH, PB .
CRITICAL CARE MEDICINE, 1992, 20 (04) :528-553
[2]   EFFECTS OF EXPIRATORY FLOW RESISTANCE ON INSPIRATORY WORK OF BREATHING [J].
BANNER, MJ ;
DOWNS, JB ;
KIRBY, RR ;
SMITH, RA ;
BOYSEN, PG ;
LAMPOTANG, S .
CHEST, 1988, 93 (04) :795-799
[3]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[4]   ADDITIONAL WORK OF BREATHING IMPOSED BY ENDOTRACHEAL-TUBES, BREATHING CIRCUITS, AND INTENSIVE-CARE VENTILATORS [J].
BERSTEN, AD ;
RUTTEN, AJ ;
VEDIG, AE ;
SKOWRONSKI, GA .
CRITICAL CARE MEDICINE, 1989, 17 (07) :671-677
[5]   INSPIRATORY WORK OF BREATHING DURING SPONTANEOUS VENTILATION USING DEMAND VALVES AND CONTINUOUS-FLOW SYSTEMS [J].
BEYDON, L ;
CHASSE, M ;
HARF, A ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 138 (02) :300-304
[7]  
BRANSON R D, 1990, Respiratory Care, V35, P1056
[8]   STUDIES ON CONTINUOUS POSITIVE AIRWAY PRESSURE BREATHING SYSTEMS [J].
COX, D ;
NIBLETT, DJ .
BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (08) :905-911
[9]  
FEELEY TW, 1975, LANCET, V2, P725
[10]   INTRINSIC PEEP AND ARTERIAL PCO2 IN STABLE PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
HALUSZKA, J ;
CHARTRAND, DA ;
GRASSINO, AE ;
MILICEMILI, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (05) :1194-1197