BIOPHYSICAL PROPERTIES OF THE GELATIN-RESORCINOL-FORMALDEHYDE GLUTARALDEHYDE ADHESIVE

被引:57
作者
ALBES, JM
KRETTEK, C
HAUSEN, B
ROHDE, R
HAVERICH, A
BORST, HG
TATOOLES, CJ
机构
[1] UNIV HLTH SCI CHICAGO MED SCH,MT SINAI MED CTR,DIV CARDIOTHORAC SURG,CHICAGO,IL 60608
[2] HANNOVER MED SCH,CTR SURG,DIV THORAC & CARDIOVASC SURG,W-3000 HANNOVER 61,GERMANY
[3] HANNOVER MED SCH,CTR SURG,DIV TRAUMA SURG,W-3000 HANNOVER 61,GERMANY
关键词
D O I
10.1016/0003-4975(93)90354-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Refixation of dissected aortic layers with gelatin-resorcin-formaldehyde/glutaraldehyde (GRFG) adhesive represents a new option in the surgical treatment of aortic dissection. Because of its ability to reinforce the delicate structures of the acutely dissected aortic wall, GRFG has been used increasingly in recent years. However, the biomechanical properties of the adhesive are still unclear, and little is known regarding the optimal mode of its application. In an ex vivo study, aortic specimens from sheep were glued with warm (45-degrees-C) adhesive under wet and dry conditions and submitted to defined degrees of compression (5 Newtons [N], 20 N). Bonded specimens were retracted to assess tensile strength and elasticity compared with two reference adhesives: cyanoacrylate gel and' fibrin glue. Gelatin-resorcin-formaldehyde/glutaraldehyde and cyanoacrylate gel showed similar results at 5 N. Both provided better adhesion when applied under dry conditions (GRFG 5 N: dry, 3.5 +/- 1.6 N/cm2; wet, 1.4 +/- 1.0 N/CM2; cyanoacrylate gel 5 N: dry, 4.8 +/- 1.8 N/cM2; wet, 3.2 +/- 1.3 N/cM2) . At 20 N, GRFG tensile strength was significantly increased for either condition compared with values at 5 N (GRFG 20 N: dry, 17.1 +/- 4.2 N/cm2; wet, 4.8 +/- 1.8 N/cm2). Fibrin glue demonstrated only weak adhesive properties even under dry conditions (fibrin glue 5 N: dry, 0.8 +/- 0.3 N/cm2). Gelatin-resorcin-formaldehyde/glutaraldehyde has good adhesive properties both in wet and dry tissue. Bonding capacity can be substantially increased when applied on dry surfaces and at increased pressures.
引用
收藏
页码:910 / 915
页数:6
相关论文
共 22 条
  • [1] BACHET J, 1982, J THORAC CARDIOV SUR, V83, P212
  • [2] BACHET J, 1988, J THORAC CARDIOV SUR, V96, P878
  • [3] BACHET J, 1990, J CARDIOVASC SURG, V31, P263
  • [4] BONCHEK LI, 1967, SURG GYNECOL OBSTETR, V125, P1301
  • [5] BONCHEK LI, 1966, ANN SURG, V165, P420
  • [6] Borst H G, 1987, Eur J Cardiothorac Surg, V1, P186, DOI 10.1016/1010-7940(87)90040-6
  • [7] BRAUNWALD NS, 1966, SURGERY, V59, P1024
  • [8] CABROL C, 1986, J THORAC CARDIOV SUR, V91, P17
  • [9] Cooper C W, 1968, Ann N Y Acad Sci, V146, P214, DOI 10.1111/j.1749-6632.1968.tb20284.x
  • [10] COOVER HW, 1959, SOC PLAST ENG J, V15, P413