LONG-TERM PERFORMANCE OF 580 HOMOGRAFT AND AUTOGRAFT VALVES USED FOR AORTIC-VALVE REPLACEMENT

被引:24
作者
BODNAR, E [1 ]
WAIN, WH [1 ]
MARTELLI, V [1 ]
ROSS, DN [1 ]
机构
[1] NATL HEART HOSP,DEPT HOMOGRAFT,LONDON W1M 8BA,ENGLAND
关键词
D O I
10.1055/s-0028-1096215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Homograft valves have been used at the National Heart Hospital since 1964, and autograft valves since 1967. The homografts were treated either by freeze drying, by flash freezing, or by tissue maintenance in a nutrient medium (fresh). In order to compare these three groups of homograft valves with the autograft valves some long term assessment of valve function was required. In the whole group of 580 valves there have been 40 late deaths, which is a probability of only 7% over 6 to 14 years. Homografts and autografts are therefore excellent valves in terms of patient survival. Thromboembolism, haemolysis and bleeding may be regarded as complications which do not occur with homograft and autograft valves. There was one thrombogenic episode in this group, an incidence of one per 11,994 patient years and a probability of only 0,000083 patient years. Potentially fatal hazards of late complications with homo or autograft valves decrease with time and at this time is a negligible factor. The similarity in pattern of onset of late infections and degeneration probably reflects the greater susceptibility to infection of a degenerating valve. All three groups of homografts are very similar and differ, only from the excellent performance of the autograft valves.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 17 条
[1]   ENHANCED VIABILITY OF FRESH AORTIC HOMOGRAFTS STORED IN NUTRIENT MEDIUM [J].
ALJANABI, N ;
ROSS, DN .
CARDIOVASCULAR RESEARCH, 1973, 7 (06) :817-822
[2]  
ANDERSON ET, 1976, J THORAC CARDIOVASC, V72, P151
[3]   ANALYSIS AND PRESENTATION OF SURGICAL RESULTS BY ACTUARIAL METHODS [J].
ANDERSON, RP ;
BONCHEK, LI ;
GRUNKEMEIER, GL ;
LAMBERT, LE ;
STARR, A .
JOURNAL OF SURGICAL RESEARCH, 1974, 16 (03) :224-230
[4]   6-YEAR REVIEW OF RESULTS OF FREEHAND AORTIC-VALVE REPLACEMENT USING AN ANTIBIOTIC STERILIZED HOMOGRAFT VALVE [J].
BARRATTBOYES, BG ;
ROCHE, AHG ;
WHITLOCK, RML .
CIRCULATION, 1977, 55 (02) :353-361
[5]  
BLACKSTONE EH, 1977, ANN THORAC SURG, V23, P302, DOI 10.1016/S0003-4975(10)64130-6
[6]  
COPELAND JG, 1977, J THORAC CARDIOV SUR, V74, P875
[7]  
Greenwood M., 1926, REPORTS PUBLIC HLTH, V33, P1
[8]   IMPROVED STATISTICAL METHOD FOR ASSESSING RESULTS OF OPERATION [J].
GRUNKEMEIER, GL ;
LAMBERT, LE ;
BONCHEK, LI ;
STARR, A .
ANNALS OF THORACIC SURGERY, 1975, 20 (03) :289-298
[9]  
LONGMORE DB, 1966, LANCET, V2, P463
[10]  
MCHENRY MM, 1978, J THORAC CARDIOV SUR, V75, P709