ANALYSIS OF PROTEINS AND GLYCOPROTEINS AT THE PICOMOLE LEVEL BY ONLINE COUPLING OF MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLOW FAST-ATOM-BOMBARDMENT AND ELECTROSPRAY MASS-SPECTROMETRY - A COMPARATIVE-EVALUATION

被引:56
作者
HEMLING, ME [1 ]
ROBERTS, GD [1 ]
JOHNSON, W [1 ]
CARR, SA [1 ]
COVEY, TR [1 ]
机构
[1] SCIEX LTD,THORNHILL L3T 1P2,ONTARIO,CANADA
来源
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY | 1990年 / 19卷 / 11期
关键词
D O I
10.1002/bms.1200191107
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A comparison of continuous‐flow fast atom bombardment (FAB) mass spectrometry and nebulization‐assisted electrospray for analysis of proteins and glycoproteins by high‐performance liquid chromatography (HPLC)/mass spectrometry is presented. The evaluation was made using enzymatic digests of recombinant soluble CD4 glycoprotein and recombinant hepatitis B surface antigen and a mixture of HPLC retention standard peptides. These samples were analyzed by reversed‐phase HPLC on a microbore (1 × 100 mm C18) gradient HPLC system with 10% or 20% of the eluent containing ∼20–100 pmol of the sample directed into the continuous‐flow FAB mass spectrometric or electrospray mass spectrometric source, respectively. The techniques were evaluated on the criteria of chromatographic integrity, ease of data analysis, protein sequence coverage, discrimination effects, ability to detect glycopeptides, simplicity of operation, and sensitivity. Both techniques produce useful peptide molecular weight data from comparable amounts of sample injected. However, the nebulization‐assisted electrospray system is capable of yielding higher peptide mapping coverages with the least sample consumed in toto due in part to the wider mass ranges resulting from the multicharging effect and to the ability to detect glycopeptides. Under the experimental conditions employed here no fragmentation was observed in the electrospray mass spectra. In contrast, significant, sequence informative fragmentation was occasionally observed for peptides in the continuous‐flow FAB mass spectral data. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:677 / 691
页数:15
相关论文
共 32 条
[1]  
BELL DJ, 1990, RAPID COMMUN MASS SP, V3, P88
[2]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[3]   CONTINUOUS-FLOW FAST ATOM BOMBARDMENT MASS-SPECTROMETRY OF PERMETHYLATED OLIGOSACCHARIDES - A COMPARATIVE-STUDY OF DIRECT MIXTURE ANALYSIS WITH PACKED CAPILLARY COLUMN LIQUID-CHROMATOGRAPHY FAST ATOM BOMBARDMENT MASS-SPECTROMETRY [J].
BOULENGUER, P ;
LEROY, Y ;
ALONSO, JM ;
MONTREUIL, J ;
RICART, G ;
COLBERT, C ;
DUQUET, D ;
DEWAELE, C ;
FOURNET, B .
ANALYTICAL BIOCHEMISTRY, 1988, 168 (01) :164-170
[4]  
BOULENGUER P, 1990, ANAL BIOCHEM, V62, P164
[5]  
BURLINGAME A, COMMUNICATION
[6]   CONTINUOUS-FLOW SAMPLE PROBE FOR FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
FAN, T ;
COTTRELL, JS .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2949-2954
[7]   CONTINUOUS-FLOW FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
MOORE, WT .
METHODS IN ENZYMOLOGY, 1990, 193 :214-237
[8]  
CARR S A, 1990, P87
[9]  
CARR SA, 1989, J BIOL CHEM, V264, P21286
[10]  
CARR SA, 1990, DRUG DELIVERY REV, V4, P113