EFFECT OF SAMPLER AND SKIMMER ORIFICE SIZE ON ANALYTE AND ANALYTE OXIDE SIGNALS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:66
作者
VAUGHAN, MA
HORLICK, G
机构
[1] Department of Chemistry, University of Alberta, Edmonton
关键词
Mass Spectrometers;
D O I
10.1016/0584-8547(90)80183-J
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The size of the orifice in the sampling cone of the interface in an inductively coupled plasma-mass spectrometer (ICP-MS) has a major impact on signal characteristics. In particular, for oxide forming elements, the MO+/M+ ratio is very dependent on orifice size. This is illustrated for a range of elements (La, Ho and Yb) as a function of nebulizer gas flow and for sampling cone orifice sizes ranging from 0.51 to 0.94 mm. In addition the size of the sampling orifice changes the shape of the signal vs nebulizer flow rate plot and this is illustrated. A curious and important observation is that the signal dependence on nebulizer flow rate is essentially identical for all analytes at any one orifice size if the analyte and analyte oxide (when observed) responses are summed. This indicates that the sampling orifice is the primary location of oxide formation in ICP-MS. Finally the effect of the skimmer orifice diameter on analyte signals is also illustrated for orifice diameters of 0.76, 0.89 and 1.0 mm in conjunction with sampling orifice sizes ranging from 0.51 to 0.94 mm. © 1990.
引用
收藏
页码:1289 / 1299
页数:11
相关论文
共 14 条
[1]   CAMPARGUE-TYPE SUPERSONIC BEAM SOURCES - ABSOLUTE INTENSITIES, SKIMMER TRANSMISSION AND SCALING LAWS FOR MONO-ATOMIC GASES HE, NE AND AR [J].
BEIJERINCK, HCW ;
VANGERWEN, RJF ;
KERSTEL, ERT ;
MARTENS, JFM ;
VANVLIEMBERGEN, EJW ;
SMITS, MRT ;
KAASHOEK, GH .
CHEMICAL PHYSICS, 1985, 96 (01) :153-173
[2]  
CRAIN JS, 1988, SPECTROCHIM ACTA B, V43, P1355
[3]   PLASMA SOURCE-MASS SPECTROMETRY USING AN INDUCTIVELY COUPLED PLASMA AND A HIGH-RESOLUTION QUADRUPOLE MASS FILTER [J].
DATE, AR ;
GRAY, AL .
ANALYST, 1981, 106 (1269) :1255-1267
[4]   AN IMPROVED INTERFACE FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
DOUGLAS, DJ ;
FRENCH, JB .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (03) :197-204
[5]   GAS-DYNAMICS OF THE INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY INTERFACE [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :743-747
[6]   STUDY OF SOLIDS DEPOSITION ON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SAMPLERS AND SKIMMERS [J].
DOUGLAS, DJ ;
KERR, LA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :749-752
[7]   INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY USING CONTINUUM FLOW ION EXTRACTION [J].
GRAY, AL ;
DATE, AR .
ANALYST, 1983, 108 (1290) :1033-1050
[8]   MASS-SPECTROMETRIC SAMPLING OF IONS FROM ATMOSPHERIC-PRESSURE FLAMES .2. AERODYNAMIC DISTURBANCE OF A FLAME BY SAMPLING SYSTEM [J].
HAYHURST, AN ;
KITTELSON, DB ;
TELFORD, NR .
COMBUSTION AND FLAME, 1977, 28 (02) :123-135
[9]   DEVELOPMENTS IN PLASMA SOURCE-MASS SPECTROMETRY [J].
HIEFTJE, GM ;
VICKERS, GH .
ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) :1-24
[10]   A NEW SENSITIVE MOLECULAR-BEAM MASS-SPECTROMETER [J].
HOGLUND, A ;
ROSENGREN, LG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 60 (SEP) :173-187