EVALUATION OF 150 CONSECUTIVE CASES OF POLY HEMA POSTERIOR CHAMBER LENSES IMPLANTED IN THE BAG USING A SMALL-INCISION TECHNIQUE

被引:22
作者
MENAPACE, R
SKORPIK, C
WEDRICH, A
机构
[1] First University Eye Hospital, Vienna
关键词
bag fixation; capsulorhexis; hydrogel lens; small-incision implantation;
D O I
10.1016/S0886-3350(13)80771-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We report the results of 150 capsular bag implantations of the IOGEL PC-12 hydrogel lens. Mean follow-up was seven months. Following capsulorhexis and phacoemulsification, a Faulkner folder was used to insert the lens through a 3.5 mm to 4.0 mm scleral tunnel incision. Initially, a number of surgical complications were encountered. Because of increasing experience and modified instrumentation and technique, these did not occur in the later cases. Visual results were good, all eyes gaining a best case visual acuity of 20/40 or better and 97% achieving 20/25 or better. Morphological results were satisfactory. Generally the lenses remained centered and at a distance from the iris. Retention of viscoelastic substance or debris between the lens and the posterior capsule, occasionally observed at the start of the series, has been avoided by retrolental aspiration. Persistent pigment dispersion, which was observed when the lens had been implanted in the sulcus, was not seen. Tolerance of the lens material was generally satisfactory. There were six cases (4%) of fibrinoid uveitis, which is a relatively high incidence. From our experience and results we conclude that this implantation procedure allowed controlled insertion and placement of the IOGEL lens, provided that adequate instrumentation and technique was used; visual performance was comparable to that of poly(methyl methacrylate) lenses; capsular bag fixation furnished satisfactory morphological results, provided an adequately shaped capsulorhexis was performed. © 1990, American Society of Cataract and Refractive Surgery. All rights reserved.
引用
收藏
页码:567 / 577
页数:11
相关论文
共 18 条
[1]  
Drews RC, Lens implantation: lessons learned from the first million, Trans Ophthalmol Soc UK, 102, pp. 505-509, (1982)
[2]  
Faulkner GD, Folding and inserting silicone intraocular lens implants, J Cataract Refract Surg, 13, pp. 678-681, (1987)
[3]  
Barrett GD, Constable IJ, Steward AD, Clinical results of hydrogel lens implantation, J Cataract Refract Surg, 12, pp. 623-631, (1986)
[4]  
Yalon M, Blumenthal M, Goldberg EP, Preliminary study of hydrophilic hydrogel intraocular lens implants in cats, Am Intra-Ocular Implant Sue J, 10, pp. 315-317, (1984)
[5]  
Heyrman TP, McDermott ML, Ubels JL, Edelhauser HF, Drug uptake and release by a hydrogel intraocular lens and the human crystalline lens, J Cataract Refract Surg, 15, pp. 169-175, (1989)
[6]  
Rochels R, Stofft E, Rasterelektronenmikroskopische Untersuchungen an weichen HEMA-Hinterkammerlinsen, Proceedings of the 2nd Congress of the Deutsche Ges. f. Intraokularlinsen Implantation, pp. 169-173, (1989)
[7]  
Skorpik C, Menapace R, Gnad HD, Et al., Evaluation of 50 silicone posterior chamber lens implantations, J Cataract Refract Surg, 13, pp. 640-643, (1987)
[8]  
Menapace R, Skorpik C, Juchem M, Et al., Evaluation of the first 60 cases of poly HEMA posterior chamber lenses implanted in the sulcus, J Cataract Refract Surg, 15, pp. 264-271, (1989)
[9]  
Percival P, Capsular bag implantation of the hydrogel lens, J Cataract Refract Surg, 13, pp. 627-629, (1987)
[10]  
Draeger J, Guthoff R, Abramo F, Zur Biomechank der Intraokularlinsen-Haptik: Vergleichende Messungen von Elastizitäts- and Rückstellkraft in Abhängigkeit von Mate rialeigenschaften und Konstruktion, Proceedings of the 2nd Congress of the Deutsche Ges. f. Intraokularlinsen Implantation, pp. 42-44, (1989)