3-PHASE BONE-SCINTIGRAPHY PATTERN OF LOOSENING IN UNCEMENTED HIP PROSTHESES

被引:14
作者
RUBELLO, D
BORSATO, N
CHIERICHETTI, F
ZANCO, P
FERLIN, G
机构
[1] Department of Nuclear Medicine, General Hospital of Castelfranco Veneto, Castelfranco Veneto (TV)
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1995年 / 22卷 / 04期
关键词
3-PHASE BONE SCAN; UNCEMENTED HIP PROSTHESIS; LOOSENING;
D O I
10.1007/BF00941844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses (UHPs) has not previously been elucidated. We evaluated 28 patients with complicated UHPs who had undergone total hip arthroplasty a very long time previously (range 3-20 years, mean 8.4). All the patients were surgically reviewed: 26 UHPs were found to be loosened and two infected. Nine asymptomatic UHPs were taken as controls, The dynamic phase was invariably negative in both loosened and asymptomatic UHPs while markedly positive in the infected ones. The blood pool phase was positive to various degrees in 16 of the 26 loosened UHPs as well as in the infected UHPs, but was invariably negative in painless replacements, In the bone phase, areas of significantly (discrete to marked) increased uptake were observed in all the loosened prostheses as well as in two-thirds of the asymptomatic ones, However, the regions of the lesser trochanter and/or tip and/or shaft were involved exclusively in the case of the loosened UHPs, and diffuse periprosthetic uptake was found only with loosened or infected implants. Areas of slight methylene diphosphonate (MDP) uptake were found at every periprosthetic site and areas of discrete to marked MDP uptake were commonly found in the acetabulum and/or the greater trochanter with both loosened and painless prostheses and are thus considered to be nonspecific findings.
引用
收藏
页码:299 / 301
页数:3
相关论文
共 6 条
[1]
BONE-SCAN APPEARANCES AFTER UNCEMENTED HIP-REPLACEMENT [J].
ASHBROOKE, AB ;
CALVERT, PT .
JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1990, 83 (12) :768-769
[2]
LULL RJ, 1983, NUCLEAR MED ANN 1983, P281
[3]
SCINTIGRAPHIC ABNORMALITIES IN PATIENTS WITH PAINFUL HIP REPLACEMENTS TREATED CONSERVATIVELY [J].
MILES, KA ;
HARPER, WM ;
FINLAY, DBL ;
BELTON, I .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (774) :491-494
[4]
OSWALD SG, 1989, J NUCL MED, V30, P1321
[5]
OSWALD SG, 1990, J NUCL MED, V31, P274
[6]
ASYMPTOMATIC TOTAL HIP-PROSTHESIS - NATURAL-HISTORY DETERMINED USING TC-99M MDP BONE SCANS [J].
UTZ, JA ;
LULL, RJ ;
GALVIN, EG .
RADIOLOGY, 1986, 161 (02) :509-512