PRECISION OF A NEW BEDSIDE METHOD FOR ESTIMATION OF THE CIRCULATING BLOOD-VOLUME

被引:18
作者
CHRISTENSEN, P
ERIKSEN, B
HENNEBERG, SW
机构
[1] Department of Anaesthesiology and Intensive Care, Odense University Hospital, Odense
关键词
BLOOD VOLUME; CARBON MONOXIDE; INTENSIVE CARE; INTERMITTENT POSITIVE PRESSURE VENTILATION; PRECISION;
D O I
10.1111/j.1399-6576.1993.tb03777.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and after ventilation with a gas mixture containing 20-50 ml of CO for a period of 10-15 min. A special Water's to and fro system was designed in order to avoid any leakage when measuring during intermittent positive pressure ventilation (IPPV). Blood samples were taken before and immediately after ventilation with the CO gas mixture. The amount of CO administered during each determination of CBV resulted in an increase in the CO saturation of hemoglobin of 2.1%-3.9%. A theoretical noise propagation analysis was performed by means of the Monte Carlo method. The analysis showed that a CO dose corresponding to an increase of less than 2% will result in an unacceptable coefficient of variation of repeated estimates. In the experimental study the coefficient of variation of repeated estimates of CBV was determined from duplicate measurements of CBV in nine healthy subjects and in nine intensive care patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration. The precision of the method is sufficient for clinical purposes.
引用
收藏
页码:622 / 627
页数:6
相关论文
共 11 条
[1]   INITIAL PLASMA DISAPPEARANCE AND DISTRIBUTION VOLUME OF [I-131]ALBUMIN AND [I-125]FIBRINOGEN IN MAN [J].
BENTHANSEN, L .
ACTA PHYSIOLOGICA SCANDINAVICA, 1989, 136 (03) :455-461
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   CONSTRUCTION OF AN INSTRUMENT FOR MORE ACCURATE, REPEATED BLOOD VOLUME DETERMINATIONS USING HSA-I-131 [J].
BOJSEN, J ;
FUNCHROS.H ;
MULLER, T .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (12) :691-&
[4]  
FENG PH, 1972, SINGAPORE MED J, V13, P106
[5]   PH EFFECT ON THE COHB ABSORPTION-SPECTRUM - IMPORTANCE FOR CALIBRATION OF THE OSM3 AND MEASUREMENT OF CIRCULATING HEMOGLOBIN AND BLOOD-VOLUME [J].
FOGHANDERSEN, N ;
THOMSEN, JK ;
FOLDAGER, N ;
SIGGAARDANDERSEN, O .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 :247-252
[7]   PLASMA-VOLUME ESTIMATION IN SEVERELY ILL INFANTS AND CHILDREN USING A SIMPLIFIED EVANS BLUE METHOD [J].
LINDERKAMP, O ;
MADER, T ;
BUTENANDT, O ;
RIEGEL, KP .
EUROPEAN JOURNAL OF PEDIATRICS, 1977, 125 (02) :135-141
[8]  
Rubinstein R.Y., 1981, SIMULATION MONTE CAR
[9]   RELIABILITY OF CLINICAL MONITORING TO ASSESS BLOOD-VOLUME IN CRITICALLY ILL PATIENTS [J].
SHIPPY, CR ;
APPEL, PL ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1984, 12 (02) :107-112
[10]   A METHOD FOR THE DETERMINATION OF THE TOTAL HAEMOGLOBIN CONTENT OF THE BODY [J].
SJOSTRAND, T .
ACTA PHYSIOLOGICA SCANDINAVICA, 1948, 16 (2-3) :211-231