COMPARISON BETWEEN MAGIC LITE(R)-SYSTEM AND CAP(R)-SYSTEM - 2 AUTOMATED SPECIFIC IGE ANTIBODY-ASSAYS

被引:72
作者
KLEINETEBBE, J
EICKHOLT, M
GATJEN, M
BRUNNEE, T
OCONNOR, A
KUNKEL, G
机构
[1] FREE UNIV BERLIN,HOSP RUDOLF VIRCHOW,DEPT CLIN IMMUNOL,AUGUSTENBURGER PLATZ 1,W-1000 BERLIN 65,GERMANY
[2] FREE UNIV BERLIN,HOSP RUDOLF VIRCHOW,ASTHMA POLIKLIN,W-1000 BERLIN 65,GERMANY
关键词
D O I
10.1111/j.1365-2222.1992.tb00150.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The MAGIC LITE system, a newly developed immunochemiluminometric assay for specific and total IgE antibody using paramagnetic particles coupled with standardized allergens as solid phase, was compared to the CAP system, a recently introduced immunoassay based on a cellulose polymer encased in a capsule. A total of 357 serum samples of patients with suspected inhalant allergies and a positive skin prick test (SPT) to common allergens (birch, timothy-grass, mugwort, cat dander, Dermatophagoides pteronyssinus, Alternaria) were investigated. Fifty SPT negative subjects served as controls (total number of tests in each assay = 1600). Both assays were highly precise (overall intra-assay and inter-assay coefficients of variation were 2.9% and 4-5% in MAGIC LITE, 4.7% and 5.5% in CAP) and showed excellent linearity (mean r2 of eightfold log2 serum dilutions were 99.7% and 99.3% in MAGIC LITE and CAP). Good correlations were found between the absolute specific IgE antibody values detected by both methods (correlation coefficient r: birth 0.86, grass 0-93, mugwort 0.96, cat 0.91, D. pteronyssinus 0.73, Alternaria 0.90). Excellent specificity (greater-than-or-equal-to 98%) occurred in both assays and with all allergens, and sensitivity was related to the allergen (MAGIC LITE/CAP): birch 91%/89%, grass 83%/90%, mugwort 50%/69%, cat 83%/83%, D. pteronyssinus 72%/78%, Alternaria 75%/81%. Our results indicate that both in vitro tests are useful tools for the detection of specific IgE antibody.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 20 条
  • [1] AXEN R, 1988, P CLIN WORKSH IGE AN, P3
  • [2] INVITRO DIAGNOSIS OF ATOPIC ALLERGY
    BERG, T
    JOHANSSON, SGO
    [J]. INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1976, 51 (04): : 471 - 481
  • [3] BERNSTEIN IL, 1988, J ALLERGY CLIN IM S3, V82, P499
  • [4] COMPARISON BETWEEN RAST AND PHARMACIA CAP SYSTEM - A NEW AUTOMATED SPECIFIC IGE ASSAY
    BOUSQUET, J
    CHANEZ, P
    CHANAL, I
    MICHEL, FB
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 85 (06) : 1039 - 1043
  • [5] BOUSQUET J, 1988, ALLERGY PRINCIPLES P, P419
  • [6] Ekins R., 1981, LIGAND Q, V4, P33
  • [7] DIAGNOSIS OF REAGINIC ALLERGY WITH HOUSE DUST, ANIMAL DANDER AND POLLEN ALLERGENS IN ADULT PATIENTS .1. COMPARISON BETWEEN RAST, SKIN-TESTS AND PROVOCATION TESTS
    ERIKSSON, NE
    AHLSTEDT, S
    BELIN, L
    [J]. INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1976, 52 (1-4): : 335 - 346
  • [8] EVALUATION OF A CAPSULATED HYDROPHILIC CARRIER POLYMER (THE IMMUNOCAP) FOR MEASUREMENT OF SPECIFIC IGE ANTIBODIES
    EWAN, PW
    COOTE, D
    [J]. ALLERGY, 1990, 45 (01) : 22 - 29
  • [9] Galen R. S., 1975, NORMALITY PREDICTIVE
  • [10] HEINIG JG, 1990, 17TH P NORD C ALL AR, P156