Optimum allocation of heat exchanger inventory of irreversible air heat pump cycles

被引:11
作者
Bi, Yuehong [1 ,2 ]
Chen, Lingen [2 ]
Sun, Fengrui [2 ]
机构
[1] Beijing Univ Technol, Inst Civil & Architectural Engn, Beijing 100124, Peoples R China
[2] Naval Univ Engn, Postgrad Sch, Wuhan 430033, Hubei, Peoples R China
基金
中国博士后科学基金;
关键词
finite-time thermodynamics; entropy generation minimization; air heat pump cycle; thermodynamic optimization; optimum allocation; heat exchanger inventory;
D O I
10.1080/14786460903556121
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study has determined the optimal ratios of heat conductance of a cold-side heat exchanger to that of a hot-side heat exchanger when the heating load and the coefficient of performance ( COP) of the irreversible air heat pump cycles are taken as the optimization objectives. Both the optimum distributions of heat conductance corresponding to the maximum heating load and the maximum COP are less than 0.5 for the fixed total heat exchanger inventory. The influences of the heat reservoir temperature ratio, the total heat exchanger inventory, and the efficiencies of the compressor and expander on the optimum distribution of heat conductance and the maximum heating load and the maximum COP are analysed and shown by numerical examples.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 39 条
[1]   PERFORMANCE OF A CARNOT REFRIGERATOR AT MAXIMUM COOLING POWER [J].
AGRAWAL, DC ;
MENON, VJ .
JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1990, 23 (22) :5319-5326
[2]   FINITE-TIME CARNOT REFRIGERATORS WITH WALL GAIN AND PRODUCT LOADS [J].
AGRAWAL, DC ;
MENON, VJ .
JOURNAL OF APPLIED PHYSICS, 1993, 74 (04) :2153-2158
[3]   THERMODYNAMICS IN FINITE-TIME [J].
ANDRESEN, B ;
SALAMON, P ;
BERRY, RS .
PHYSICS TODAY, 1984, 37 (09) :62-70
[4]  
Andresen B, 1983, FINITE TIME THERMODY
[5]   AN ECOLOGICAL OPTIMIZATION CRITERION FOR FINITE-TIME HEAT ENGINES [J].
ANGULOBROWN, F .
JOURNAL OF APPLIED PHYSICS, 1991, 69 (11) :7465-7469
[6]   Thermoeconomic considerations in the optimum allocation of heat transfer inventory for refrigeration and heat pump systems [J].
Antar, MA ;
Zubair, SM .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2002, 124 (01) :28-33
[7]   Thermoeconomic considerations in the optimum allocation of heat exchanger inventory for a power plant [J].
Antar, MA ;
Zubair, SM .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (10) :1169-1179
[9]   OPTIMAL ALLOCATION OF A HEAT-EXCHANGER INVENTORY IN HEAT DRIVEN REFRIGERATORS [J].
BEJAN, A ;
VARGAS, JVC ;
SOKOLOV, M .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1995, 38 (16) :2997-3004
[10]   POWER AND REFRIGERATION PLANTS FOR MINIMUM HEAT-EXCHANGER INVENTORY [J].
BEJAN, A .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1993, 115 (02) :148-150