EVALUATION OF MODELS FOR SIZE-EXCLUSION CHROMATOGRAPHY OF ASYMMETRIC SOLUTES

被引:7
作者
KUNTZ, MA [1 ]
DUBIN, PL [1 ]
KAPLAN, JI [1 ]
MEHTA, MS [1 ]
机构
[1] INDIANA UNIV PURDUE UNIV,DEPT CHEM,INDIANAPOLIS,IN 46205
关键词
D O I
10.1021/j100079a028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We consider two presentations regarding the size exclusion chromatography of highly asymmetric solutes: one is embodied in the statistical model of Giddings et al.; the second is described by the concept of ''end-on insertion'' proposed by Tanford and expanded upon by Meredith and Nathans. Our evaluation is based on measurements of K-sec for the rigid rodlike and spherical solutes schizophyllan and ficoll, respectively, and also on measurements of the experimental flow rate dependence of K-sec. The concept of ''end-on insertion'', as differentiated from standard statistical equilibrium considerations, does not seem to be defensible on fundamental grounds, However, the equilibrium ''random pore'' treatment of Giddings yields relationships which are incompatible with the current results. The role of the dynamics of solute motion is discussed vis-a-vis hypothetical limitations of equilibrium models.
引用
收藏
页码:7063 / 7067
页数:5
相关论文
共 29 条
[1]  
ACKERS GK, 1964, BIOCHEMISTRY-US, V3, P724
[2]   FLOW-RATE DEPENDENCE OF ELUTION VOLUMES IN SIZE EXCLUSION CHROMATOGRAPHY - A REVIEW [J].
AUBERT, JH ;
TIRRELL, M .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 :219-249
[3]  
BRUMBAUG.EE, 1968, J BIOL CHEM, V243, P6315
[4]  
Cantor CR, 1980, BIOPHYSICAL CHEM 2
[5]   THEORETICAL MODELS FOR PEAK MIGRATION IN GEL PERMEATION CHROMATOGRAPHY [J].
CASASSA, EF .
JOURNAL OF PHYSICAL CHEMISTRY, 1971, 75 (26) :3929-+
[6]   SIZE EXCLUSION CHROMATOGRAPHY OF POLYMER-MOLECULES ON MICROPARTICULATE SILICA-GELS - A COMPARATIVE-STUDY [J].
CHIANTORE, O ;
GUAITA, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 260 (01) :41-49
[7]   INFLUENCE OF IONIC-STRENGTH AND COMPOSITION ON THE SIZE OF MIXED MICELLES OF SODIUM DODECYL-SULFATE AND TRITON-X-100 [J].
DUBIN, PL ;
PRINCIPI, JM ;
SMITH, BA ;
FALLON, MA .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1989, 127 (02) :558-565
[8]   FAILURE OF UNIVERSAL CALIBRATION FOR SIZE EXCLUSION CHROMATOGRAPHY OF RODLIKE MACROMOLECULES VERSUS RANDOM COILS AND GLOBULAR-PROTEINS [J].
DUBIN, PL ;
PRINCIPI, JM .
MACROMOLECULES, 1989, 22 (04) :1891-1896
[9]   QUANTITATION OF NONIDEAL BEHAVIOR IN PROTEIN SIZE-EXCLUSION CHROMATOGRAPHY [J].
DUBIN, PL ;
EDWARDS, SL ;
MEHTA, MS ;
TOMALIA, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 635 (01) :51-60
[10]   SIZE-EXCLUSION CHROMATOGRAPHY DIMENSION FOR ROD-LIKE MACROMOLECULES [J].
DUBIN, PL ;
KAPLAN, JI ;
TIAN, BS ;
MEHTA, M .
JOURNAL OF CHROMATOGRAPHY, 1990, 515 :37-42