DOPPLER GUIDED EXTRATHORACIC INTRODUCER INSERTION

被引:21
作者
FYKE, FE [1 ]
机构
[1] MISSISSIPPI BAPTIST MED CTR,JACKSON,MS
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 05期
关键词
SUBCLAVIAN VENIPUNCTURE; PACEMAKER IMPLANTATION; PACEMAKER LEAD INSERTION; DOPPLER FLOW DETECTION;
D O I
10.1111/j.1540-8159.1995.tb04742.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent reports have raised concern over the use of standard subclavian puncture for placement of permanent pacing leads. This study reports the initial experience of one implanter in 59 consecutive, unselected patients undergoing implantation of a variety of pacing leads in whom a simple Doppler flow detector was used to guide extrathoracic venipuncture of the lateral subclavian/axillary vein. A total of 100 leads were placed for 48 right- and 11 left-sided systems. Lead insertion by this technique was successful in all patients. One small pneumothorax and two uncomplicated arterial punctures occurred. One patient's leads were revised electively because of unacceptable loss of redundancy when standing. There have been no infections or other late complications. A simple Doppler flow detector appears to be useful in identifying the lateral subclavian/axillary vein for extrathoracic pacemaker lead placement.
引用
收藏
页码:1017 / 1021
页数:5
相关论文
共 17 条
[1]   THE PINCH-OFF SIGN - A WARNING OF IMPENDING PROBLEMS WITH PERMANENT SUBCLAVIAN CATHETERS [J].
AITKEN, DR ;
MINTON, JP .
AMERICAN JOURNAL OF SURGERY, 1984, 148 (05) :633-636
[2]   A VARIATION ON THE INTRODUCER TECHNIQUE FOR UNLIMITED ACCESS TO THE SUBCLAVIAN VEIN [J].
BELOTT, PH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (01) :43-48
[3]   SURVEY OF CARDIAC PACING IN THE UNITED-STATES IN 1989 [J].
BERNSTEIN, AD ;
PARSONNET, V .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (04) :331-338
[4]   CLINICAL-EXPERIENCE WITH THE EXTRATHORACIC INTRODUCER INSERTION TECHNIQUE [J].
BYRD, CL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (09) :1781-1784
[5]   ULTRASOUND-ASSISTED CANNULATION OF THE INTERNAL JUGULAR-VEIN - A PROSPECTIVE COMPARISON TO THE EXTERNAL LANDMARK-GUIDED TECHNIQUE [J].
DENYS, BG ;
URETSKY, BF ;
REDDY, PS .
CIRCULATION, 1993, 87 (05) :1557-1562
[6]   SUBCLAVIAN PUNCTURE FOR PACEMAKER LEAD PLACEMENT [J].
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (04) :467-467
[7]  
HAYES DL, 1991, CARDIOLOGY FUNDAMENT, P1025
[8]   ANATOMICAL AND MORPHOLOGICAL EVALUATION OF PACEMAKER LEAD COMPRESSION [J].
JACOBS, DM ;
FINK, AS ;
MILLER, RP ;
ANDERSON, WR ;
MCVENES, RD ;
LESSAR, JF ;
COBIAN, KE ;
STAFFANSON, DB ;
UPTON, JE ;
BUBRICK, MP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03) :434-444
[9]   DOPPLER LOCALIZATION OF THE INTERNAL JUGULAR VEIN FACILITATES CENTRAL VENOUS CANNULATION [J].
LEGLER, D ;
NUGENT, M .
ANESTHESIOLOGY, 1984, 60 (05) :481-482
[10]   SAFE JUGULAR AND SUBCLAVIAN VENIPUNCTURE UNDER ULTRASONOGRAPHIC GUIDANCE [J].
MACHI, J ;
TAKEDA, J ;
KAKEGAWA, T .
AMERICAN JOURNAL OF SURGERY, 1987, 153 (03) :321-326