A REFERENCE METHOD FOR CORRELATION OF ANATOMIC AND FUNCTIONAL BRAIN IMAGES - VALIDATION AND CLINICAL-APPLICATION

被引:25
作者
MOUNTZ, JM [1 ]
ZHANG, B [1 ]
LIU, HG [1 ]
INAMPUDI, C [1 ]
机构
[1] UNIV ALABAMA,MED CTR,DEPT RADIOL,DIV NUCL MED,BIRMINGHAM,AL 35294
关键词
D O I
10.1016/S0001-2998(05)80018-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe a reference device that provides accurate correlation between anatomic and functional brain images. The reference device, which generates fiduciary reference points on sequential scan planes, is positioned adjacent to the canthomeatal line of the subject and held in place by a glasses-like framework anchored to the external auditory meatus. The reference system was tested on 17 subjects undergoing 99mTc hexamethylpropylene amine oxime ([99mTc]HMPAO) brain single-photon emission computed tomography (SPECT) and cranial computed tomography (CT) scans. The centers of the caudate nuclei, thalami, brain stem, and cerebellar vermis were identified independently on CT and SPECT. The average difference +/-1 SD between structure locations (x,y, and z) on SPECT and CT were calculated as 1.86 +/- 1.5, 2.16 +/- 1.4, and 1.83 +/- 1.9 mm, respectively. The clinical application of the method is showed by coregistration of images from SPECT to MRI. An example of sequential [99mTc]HMPAO brain SPECT scan sections precisely coregistered with MRI scan sections oriented parallel to and sequentially above the canthomeatal line illustrates the correlation between regional cerebral blood flow (rCBF) tracer activity on SPECT and normal anatomic structures. Test-retest activation paradigms in brain SPECT requires precise SPECT-to-SPECT image coregistration to evaluate changes in rCBF during activation. Precisely coregistered rest, 48-hour repeat rest [99mTc]HMPAO SPECT studies are shown to illustrate the normal intrasubject variability of tracer uptake. An example of the usefulness of image coregistration for evaluation of viable residual brain tumor and its application to tumor biopsy is presented. An example of developmental abnormalities identified by [99mTc]HMPAO brain SPECT is illustrated by a case of autistic disorder. An example of image coregistration in stroke and evaluation of cerebrovascular disease with Diamox (Lederle Laboratory Division, Pearl River, NY) cerebrovasculature stress testing is presented. The usefulness in epilepsy using a protocol whereby the tracer is injected during the ictal phase of seizure is presented. We conclude that the reference system provides an accurate, rapid, and noninvasive patient-specific method for correlating brain structure with brain function.
引用
收藏
页码:256 / 271
页数:16
相关论文
共 23 条
[1]  
BERKOVIC SF, 1992, EPILEPSY SURGERY, P251
[2]   USE OF TL-201 SPECT TO QUANTITATE MALIGNANCY GRADE OF GLIOMAS [J].
BLACK, KL ;
HAWKINS, RA ;
KIM, KT ;
BECKER, DP ;
LERNER, C ;
MARCIANO, D .
JOURNAL OF NEUROSURGERY, 1989, 71 (03) :342-346
[3]   A COMPUTERIZED ADJUSTABLE BRAIN ATLAS [J].
BOHM, C ;
GREITZ, T ;
ERIKSSON, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :687-689
[4]   PARIETAL LOBE ABNORMALITIES DETECTED WITH MR IN PATIENTS WITH INFANTILE-AUTISM [J].
COURCHESNE, E ;
PRESS, GA ;
YEUNGCOURCHESNE, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) :387-393
[5]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530
[6]   A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
PERLMUTTER, JS ;
RAICHLE, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :141-153
[7]   ENHANCED DETECTION OF FOCAL BRAIN RESPONSES USING INTERSUBJECT AVERAGING AND CHANGE-DISTRIBUTION ANALYSIS OF SUBTRACTED PET IMAGES [J].
FOX, PT ;
MINTUN, MA ;
REIMAN, EM ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (05) :642-653
[8]   A COMPUTERIZED BRAIN ATLAS - CONSTRUCTION, ANATOMICAL CONTENT, AND SOME APPLICATIONS [J].
GREITZ, T ;
BOHM, C ;
HOLTE, S ;
ERIKSSON, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (01) :26-38
[9]  
KIM KT, 1990, J NUCL MED, V31, P965
[10]  
KUNG HF, 1990, J NUCL MED, V31, P573