MICROLEAKAGE IN ALLOY-GLASS IONOMER LINED AMALGAM RESTORATIONS AFTER THERMOCYCLING

被引:16
作者
ARCORIA, CJ [1 ]
FISHER, MA [1 ]
WAGNER, MJ [1 ]
机构
[1] BAYLOR COLL DENT, DEPT BIOCHEM, DALLAS, TX 75246 USA
关键词
D O I
10.1111/j.1365-2842.1991.tb00025.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Marginal microleakage was measured around amalgam restorations lined with alloyglass ionomer cement and coated with a glass ionomer varnish. Preparations were made in 48 human extracted mandibular molar teeth. Alloy-glass ionomer liners and varnishes were placed into selected preparations. Tytin amalgam was inserted into all of the teeth and left unburnished and unpolished. Half of the total samples were thermocycled for 5 days and the remainder were left in deionized water. The teeth were immersed in a 0.5% methylene blue dye and sectioned vertically with a diamond saw. Microleakage was scored visually at x 100 magnification, and the data were analysed using the Mann-Whitney U-test (P less-than-or-equal-to 0.05). Thermocycling did not have a significant effect on microleakage, except when both an alloy-glass ionomer liner and varnish were used. Overall, the use of an alloy-glass ionomer liner made the most significant difference in reducing microleakage.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 22 条
[1]   EFFECTS OF THERMOCYCLING ON AMALGAM AND ALLOY-GLASS IONOMER CORES LUTED TO CAST GOLD CROWNS [J].
ARCORIA, CJ ;
DEWALD, JP ;
MOODY, CR ;
FERRACANE, JL .
DENTAL MATERIALS, 1988, 4 (03) :155-157
[2]   EFFECT OF GLASS-IONOMER BASE ON COMPOSITE RESIN HARDNESS [J].
BERRONG, JM ;
COOLEY, RL ;
DUKE, ES .
DENTAL MATERIALS, 1989, 5 (01) :38-40
[3]   A VISIBLE LIGHT-CURED POSTERIOR COMPOSITE RESIN - RESULTS OF A 3-YEAR CLINICAL-EVALUATION [J].
BOKSMAN, L ;
JORDAN, RE ;
SUZUKI, M ;
CHARLES, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1986, 112 (05) :627-631
[4]   THERMAL FATIGUE IN TEETH [J].
BROWN, WS ;
THOMPSON, RE ;
JACOBS, HR .
JOURNAL OF DENTAL RESEARCH, 1972, 51 (02) :461-&
[5]  
CRAIG RG, 1975, RESTORATIVE DENTAL M, P165
[6]   MICROLEAKAGE - THE EFFECT OF STORAGE AND CYCLING DURATION [J].
CRIM, GA ;
GARCIAGODOY, F .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05) :574-576
[7]  
DeWald J P, 1988, Quintessence Int, V19, P619
[8]  
Garcia-Godoy F, 1988, Am J Dent, V1, P53
[9]   INVITRO STUDY OF CERTAIN PROPERTIES OF A GLASS IONOMER CEMENT [J].
MALDONADO, A ;
SWARTZ, ML ;
PHILLIPS, RW .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1978, 96 (05) :785-791
[10]  
MATHIS RS, 1988, J DENT RES, V67, P662