A PARTIALLY AUTOMATED RADIOLIGAND BINDING ASSAY SYSTEM FOR USE IN CLINICAL AND PHARMACEUTICAL RESEARCH

被引:3
作者
LIEBL, B
ANHAUPL, T
HAEN, E
GUNSTER, B
GEORGIEFF, M
机构
[1] TECAN ROBOT,ZINSSER ANALYT,FRANKFURT,GERMANY
[2] UNIV ULM,ANASTHESIOL KLIN,W-7900 ULM,GERMANY
来源
JOURNAL OF RECEPTOR RESEARCH | 1993年 / 13卷 / 1-4期
关键词
D O I
10.3109/10799899309073667
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Using a Tecan robotic sample processor and IBM compatible PCs we have developed a flexible, partially automated radioligand binding assay system. It handles pipetting parameters of up to 16 saturation or competition experiments at a time with up to 24 radioligand- or competitor-concentrations in a range over 4 orders of magnitude per experiment. The system provides enough flexibility so that all pipetting parameters including different tube-, rack-sizes, sample volumina and pipetting sequences may be easily adapted to the large variety of experimental requirements in binding assays. It rationalizes and increases assay throughput (up to 70% spare of working time), improves reliance and reproducibility of results. Radioactive exposure is minimized to the time preparing the radioligand working solution and transferring the sample tubes to and from the sample processor. The system has proven effective in various investigations on binding interactions, as well as in clinical studies on receptor expression under physiologic, pathological and therapeutic conditions.
引用
收藏
页码:369 / 378
页数:10
相关论文
共 11 条
[1]   KINETIC AND EQUILIBRIUM STUDIES OF IODOCYANOPINDOLOL(-)125 BINDING TO BETA-ADRENOCEPTORS ON HUMAN-LYMPHOCYTES - EVIDENCE FOR THE EXISTENCE OF 2 CLASSES OF BINDING-SITES [J].
ANHAUPL, T ;
LIEBL, B ;
REMIEN, J .
JOURNAL OF RECEPTOR RESEARCH, 1988, 8 (1-4) :47-57
[2]   REVISED RADIORECEPTOR ASSAY FOR BETA-2-ADRENOCEPTORS EXPRESSED ON PERIPHERAL MONONUCLEAR LEUKOCYTES [J].
HAEN, E ;
LIEBL, B ;
LEDERER, T ;
PLISKA, V .
JOURNAL OF RECEPTOR RESEARCH, 1991, 11 (1-4) :129-140
[3]   NOCTURNAL ASTHMA - BETA-2-ADRENOCEPTORS ON PERIPHERAL MONONUCLEAR LEUKOCYTES, CAMP-PLASMA AND CORTISOL-PLASMA CONCENTRATIONS [J].
HAEN, E ;
HAUCK, R ;
EMSLANDER, HP ;
LANGENMAYER, I ;
LIEBL, B ;
SCHOPOHL, J ;
REMIEN, J ;
FRUHMANN, G .
CHEST, 1991, 100 (05) :1239-1245
[4]  
HAEN E, 1989, ATEMWEG LUNGENKRANK, V15, P387
[5]  
HAEN E, 1989, ALLERGOL S, V12, P7
[6]  
LANGENMAYER I, 1990, ATEMWEG LUNGENKRANK, V16, P278
[7]   THE USE OF ROBOTS AND COMPUTERS IN THE ORGANIZATION OF STUDIES ON THE CIRCADIAN VARIATION OF BETA2-ADRENOCEPTOR SITES IN PERIPHERAL MONONUCLEAR LEUKOCYTES [J].
LIEBL, B ;
HAEN, E ;
ROMACKER, U ;
NGUYEN, PT ;
REMIEN, J .
CHRONOBIOLOGY INTERNATIONAL, 1990, 7 (03) :235-238
[8]   EFFECT OF THIOLS ON BETA-2-ADRENOCEPTORS IN HUMAN MONONUCLEAR LEUKOCYTES [J].
LIEBL, B ;
ANHAUPL, T ;
HAEN, E ;
REMIEN, J .
NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1988, 338 (05) :523-528
[9]  
LIEBL B, 1989, Naunyn-Schmiedeberg's Archives of Pharmacology, V339, pR92
[10]  
TRUNK E, 1991, ANASTHESIST S, V40, P108