QUANTITATIVE SENSITIVITY OF ULTRASOUND IN DETECTING FREE INTRAPERITONEAL FLUID

被引:166
作者
BRANNEY, SW
WOLFE, RE
MOORE, EE
ALBERT, NP
HEINIG, M
MESTEK, M
EULE, J
机构
[1] DENVER HLTH & HOSP RESIDENCY EMERGENCY MED,DENVER,CO
[2] BRIGHAM & WOMENS HOSP,BOSTON,MA 02115
[3] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
[4] UNIV COLORADO,HLTH SCI CTR,DENVER,CO
关键词
D O I
10.1097/00005373-199508000-00032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The minimum volume of intraperitoneal fluid that is detectable in Morison's pouch with ultrasound in the trauma setting is not well defined. To evaluate this question, we used diagnostic peritoneal lavage (DPL) as a model for intraperitoneal hemorrhage and undertook a blinded prospective study of the sensitivity of ultrasound in detecting intraperitoneal fluid, Participants included attending physicians and residents in emergency medicine, radiology, and surgery, During the infusion of the DPL fluid, participants continuously scanned Morison's pouch until they detected fluid, All participants were blinded to the rate of infusion and the volume infused, One hundred patients were entered into the study, The mean volume of fluid detected was 619 mt. Only 10% of participants detected fluid volumes less than 400 mL and the overall sensitivity at one liter was 97%. We conclude that reliable detection of intraperitoneal fluid in Morison's pouch requires a greater volume than has been previously described.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 30 条
  • [1] ABDOMINAL ULTRASOUND AS A RELIABLE INDICATOR FOR CONCLUSIVE LAPAROTOMY IN BLUNT ABDOMINAL-TRAUMA
    BODE, PJ
    NIEZEN, RA
    VANVUGT, AB
    SCHIPPER, J
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (01) : 27 - 31
  • [2] DOCK W, 1988, UNFALLCHIRURG, V91, P185
  • [3] DIAGNOSTIC PERITONEAL LAVAGE IN BLUNT ABDOMINAL-TRAUMA
    ENGRAV, LH
    BENJAMIN, CI
    STRATE, RG
    PERRY, JF
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1975, 15 (10) : 854 - 859
  • [4] DETECTABILITY OF INTRAPERITONEAL FLUID BY ULTRASONOGRAPHY - AN EXPERIMENTAL INVESTIGATION
    FORSBY, J
    HENRIKSSON, L
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1984, 25 (05): : 375 - 378
  • [5] FORSTER R, 1993, J TRAUMA, V34, P264
  • [6] ABDOMINAL LAVAGE IN BLUNT TRAUMA
    GILL, W
    CHAMPION, HR
    LONG, WB
    JAMARIS, J
    COWLEY, RA
    [J]. BRITISH JOURNAL OF SURGERY, 1975, 62 (02) : 121 - 124
  • [7] EVALUATION OF ASCITES BY ULTRASOUND
    GOLDBERG, BB
    GOODMAN, GA
    CLEARFIELD, HR
    [J]. RADIOLOGY, 1970, 96 (01) : 15 - +
  • [8] THE ROLE OF ULTRASONOGRAPHY IN BLUNT ABDOMINAL-TRAUMA - RESULTS IN 250 CONSECUTIVE CASES
    GOLETTI, O
    GHISELLI, G
    LIPPOLIS, PV
    CHIARUGI, M
    BRACCINI, G
    MACALUSO, C
    CAVINA, E
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 36 (02) : 178 - 181
  • [9] GRUESSNER R, 1989, J TRAUMA, V29, P242
  • [10] HALBFASS HJ, 1981, FORTSCHR MED, V99, P1681