COMPARISON OF 2 METHODS FOR CORRECTING OCULAR ARTIFACTS IN EEGS

被引:12
作者
VANDENBERGLENSSEN, MMC
VANGISBERGEN, JAM
JERVIS, BW
机构
[1] EINDHOVEN UNIV TECHNOL,DIV MED ELECT ENGN,5600 MB EINDHOVEN,NETHERLANDS
[2] SHEFFIELD HALLAM UNIV,SCH ENGN INFORM TECHNOL,DIV ELECTR ENGN,SHEFFIELD,S YORKSHIRE,ENGLAND
关键词
ARTIFACT REMOVAL; EEG; EOG; EVENT-RELATED POTENTIAL; OCULAR ARTIFACT;
D O I
10.1007/BF02515308
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A major problem in the study of brain potentials is the occurrence of ocular artefacts in electro-encephalograms. OAs can be monitored by placing electrodes near the eyes and recording electro-oculograms. In the paper, two OA correction methods based on simulations are compared; the Jervis method and the vandenBerg method. In most simulations, the residual (the difference between the original EEG and EEG after correction) is smaller in amplitude and variance for the vandenBerg method than for the Jervis method. When eye movements and blinks are given different factors, the blinks are not removed completely. For both methods, the residual of the blinks and for eye movements. The occurrence of a slow negative wave greatly disturbs the estimated parameters and thus the residuals of the Jervis method. For the vandenBerg method, there is only a very small effect. The conclusion from correcting a recorded data set, which does not contain a slow negative wave, is that, for these data, there is no evidence that one method is better than the other.
引用
收藏
页码:501 / 511
页数:11
相关论文
共 19 条
[1]  
Barlow J., 1986, HDB ELECTROENCEPHALO, P15
[2]  
BROWNLEE KA, 1965, STATISTICAL THEORY M
[3]  
Brunia C H M, 1989, J PSYCHOPHYSIOL, V3, P1
[4]   DIFFERENTIAL CONTRIBUTIONS OF BLINKS AND VERTICAL EYE-MOVEMENTS AS ARTIFACTS IN EEG RECORDING [J].
CORBY, JC ;
KOPELL, BS .
PSYCHOPHYSIOLOGY, 1972, 9 (06) :640-&
[5]  
DEWIT HJF, 1985, THESIS EINDHOVEN U T
[6]   THE TRANSFER OF EOG ACTIVITY INTO THE EEG FOR EYES OPEN AND CLOSED [J].
GASSER, T ;
SROKA, L ;
MOCKS, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (02) :181-193
[7]   A NEW METHOD FOR OFF-LINE REMOVAL OF OCULAR ARTIFACT [J].
GRATTON, G ;
COLES, MGH ;
DONCHIN, E .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 55 (04) :468-484
[8]  
HILLYARD SA, 1970, ELECTROENCEPHALOGR C, V28, P17
[9]   A NEW MICROCOMPUTER-BASED ONLINE OCULAR ARTIFACT REMOVAL (OAR) SYSTEM [J].
IFEACHOR, EC ;
JERVIS, BW ;
MORRIS, EL ;
ALLEN, EM ;
HUDSON, NR .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1986, 133 (05) :291-300
[10]   INVESTIGATION AND COMPARISON OF SOME MODELS FOR REMOVING OCULAR ARTIFACTS FROM EEG SIGNALS .2. QUANTITATIVE AND PICTORIAL COMPARISON OF MODELS [J].
IFEACHOR, EC ;
JERVIS, BW ;
ALLEN, EM ;
MORRIS, EL ;
WRIGHT, DE ;
HUDSON, NR .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (06) :591-598