EPIDEMIC BACTEREMIA DUE TO ACINETOBACTER-BAUMANNII IN 5 INTENSIVE-CARE UNITS

被引:148
作者
BECKSAGUE, CM
JARVIS, WR
BROOK, JH
CULVER, DH
POTTS, A
GAY, E
SHOTTS, BW
HILL, B
ANDERSON, RL
WEINSTEIN, MP
机构
[1] STATE DEPT HLTH, TRENTON, NJ USA
[2] UNIV MED & DENT NEW JERSEY, DEPT COMMUNITY HLTH, NEW BRUNSWICK, NJ 08903 USA
[3] UNIV MED & DENT NEW JERSEY, DEPT MED, NEW BRUNSWICK, NJ 08903 USA
[4] UNIV MED & DENT NEW JERSEY, DEPT PATHOL, NEW BRUNSWICK, NJ 08903 USA
关键词
Acinetobacter; Bacteremia; Cross infection; Equipment safety; Intensive care units;
D O I
10.1093/oxfordjournals.aje.a115714
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
From March 5, 1986 to September 4, 1987, Acinetobacter baumannii (AB) was isolated from blood or vascular catheter-tip cultures of 75 patients in five intensive care units at a hospital in New Jersey. To identify risk factors for AB bacteremia in the intensive care units, a case-control study was conducted. Characteristics of 72 case-patients were compared with those of 37 controls. Case-patients were more likely than controls to have had peripheral arterial catheters (odds ratio (OR)= 7.0, p < 0.001), mechanical ventilation (OR= 5.8, p < 0.001), hyperali-mentation (OR= 5.7, p < 0.001), or pulmonary arterial catheters (OR= 3.9, p < 0.001). Arterial catheters were used with reusable pressure transducers for intravascular pressure monitoring. A logistic regression analysis identified four independent risk factors: transducers, ventilation, hyperalimentation, and days of transducer use at an insertion site. The strongest influence on the risk of AB bacteremia was exerted by number of days of transducer usage. Cultures of 70 transducer diaphragms or domes, 42 in-use and 28 in-storage, were positive for AB in 21% and 46%, respectively. Plasmid analysis showed that patient blood cultures and transducer isolates were identical. Transducers were wiped with alcohol in the units between patient uses. Since reusable transducers appeared to be the source of this outbreak, it is recommended that reusable transducers receive either high level disinfection or sterilization between patient uses. © 1990 by The Johns Hopkins University School of Hygiene and Public Health.
引用
收藏
页码:723 / 733
页数:11
相关论文
共 34 条
[1]
NOSOCOMIAL BACTEREMIA ASSOCIATED WITH CONTAMINATED BLOOD-PRESSURE TRANSDUCERS - REPORT OF AN OUTBREAK AND A REVIEW OF THE LITERATURE [J].
ADUAN, RP ;
IANNINI, PB ;
SALAKI, J .
AMERICAN JOURNAL OF INFECTION CONTROL, 1980, 8 (02) :33-40
[2]
INFECTIONS CAUSED BY ARTERIAL CATHETERS USED FOR HEMODYNAMIC MONITORING [J].
BAND, JD ;
MAKI, DG .
AMERICAN JOURNAL OF MEDICINE, 1979, 67 (05) :735-741
[3]
AN ATYPICAL STRAIN OF SPOROTHRIX FROM SOUTH AFRICA [J].
BRANDT, FA ;
VANNIEKE.V .
JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1968, 96 (01) :39-&
[4]
BECKSAGUE CM, 1989, INFECT CONT HOSP EP, V10, P54, DOI 10.1086/645961
[5]
BECKSAGUE CM, 1988, OCT INT C ANT AG CHE, P91950
[6]
TAXONOMY OF THE GENUS ACINETOBACTER WITH THE RECOGNITION OF ACINETOBACTER-BAUMANNII SP-NOV, ACINETOBACTER-HAEMOLYTICUS SP-NOV, ACINETOBACTER-JOHNSONII SP-NOV, AND ACINETOBACTER-JUNII SP-NOV AND EMENDED DESCRIPTIONS OF ACINETOBACTER-CALCOACETICUS AND ACINETOBACTER-LWOFFII [J].
BOUVET, PJM ;
GRIMONT, PAD .
INTERNATIONAL JOURNAL OF SYSTEMATIC BACTERIOLOGY, 1986, 36 (02) :228-240
[7]
FAILURE OF DISPOSABLE DOMES TO PREVENT SEPTICEMIA ACQUIRED FROM CONTAMINATED PRESSURE TRANSDUCERS [J].
BUXTON, AE ;
ANDERSON, RL ;
KLIMEK, J ;
QUINTILIANI, R .
CHEST, 1978, 74 (05) :508-513
[8]
CASTLE M, 1978, HEART LUNG, V7, P641
[9]
DEAN AG, 1987, EPI INFO VERSION 3 M, P91950
[10]
Fleiss JL., 1981, STAT METHODS RATES P, V2