IN-FLIGHT CAPTURE OF AN ION-BEAM IN A PAUL TRAP

被引:37
作者
MOORE, RB
ROULEAU, G
机构
[1] Foster Radiation Laboratory, McGill University, Montreal, QC
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1080/09500349214550351
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A system for collecting 60 keV ion beams was set up at the ISOLDE-3 radionuclide mass-separator facility at CERN. Electric field retardation was used to bring the ions to 20 eV for injection into a Paul trap. Tests were made with Xe-132+ and Br-79- ions. A trap potential well depth of about 30 V could be created. At this well depth a collection efficiency of about 0.2% was obtained for a xenon beam of emittance about 2-pi mm-mrad and energy spread estimate to be of a few electronvolts. The efficiency for bromine ions was less, but still appreciable. The efficiencies achieved indicate that a sizeable fraction of the ions arriving at the correct rf window for acceptance by the trap were being collected. To the limit of the apparatus, the efficiency was increasing in proportion of the third power of the rf amplitude applied to the trap, indicating that it was proportional to the phase space volume of the trap. These results are now being used to design a larger Paul trap collection system for installation at the ISOLDE-BOOSTER facility. By including a pre-bunching system to fit an incoming dc beam to the rf acceptance, it is expected that almost complete collection of weak mass-separated high-velocity beams can be achieved.
引用
收藏
页码:361 / 371
页数:11
相关论文
共 14 条
[1]  
BERKEL GJV, 1990, ANAL CHEM, V62, P1284
[2]   MASS DETERMINATION OF FRANCIUM AND RADIUM ISOTOPES BY A PENNING TRAP MASS-SPECTROMETER [J].
BOLLEN, G ;
KLUGE, HJ ;
OTTO, T ;
SAVARD, G ;
SCHWEIKHARD, L ;
STOLZENBERG, H ;
AUDI, G ;
MOORE, RB ;
ROULEAU, G .
JOURNAL OF MODERN OPTICS, 1992, 39 (02) :257-262
[3]   TRAPPING OF IONS FROM HIGH-ENERGY SOURCES INTO A RADIOFREQUENCY ION TRAP [J].
COUTANDIN, J ;
WERTH, G .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 29 (02) :89-92
[4]  
DAWSON PH, 1970, Patent No. 3521939
[5]  
Dehmelt H. G., 1969, Advances in atomic and molecular physics vol.5, P109, DOI 10.1016/S0065-2199(08)60156-6
[6]   ION-BEAM STUDIES .1. RETARDATION OF ION-BEAMS TO VERY LOW ENERGIES IN AN IMPLANTATION ACCELERATOR [J].
FREEMAN, JH ;
TEMPLE, W ;
BEANLAND, D ;
GARD, GA .
NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (01) :1-11
[7]   THOUSANDFOLD IMPROVEMENT IN THE MEASURED ANTIPROTON MASS [J].
GABRIELSE, G ;
FEI, X ;
OROZCO, LA ;
TJOELKER, RL ;
HAAS, J ;
KALINOWSKY, H ;
TRAINOR, TA ;
KELLS, W .
PHYSICAL REVIEW LETTERS, 1990, 65 (11) :1317-1320
[8]  
KISHORE MN, 1976, INT J MASS SPECTROM, V29, P345
[9]   INJECTION OF IONS INTO A QUADRUPOLE ION TRAP MASS-SPECTROMETER [J].
LOURIS, JN ;
AMY, JW ;
RIDLEY, TY ;
COOKS, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 88 (2-3) :97-111
[10]   THE TEMPERATURE OF BUFFER-GAS COOLED IONS IN A PAUL TRAP [J].
LUNNEY, MDN ;
BUCHINGER, F ;
MOORE, RB .
JOURNAL OF MODERN OPTICS, 1992, 39 (02) :349-360